background image

1 (20)

WaterFuse® - House  

User Manual

&

Installation Instruction

Содержание WaterFuse - House

Страница 1: ...1 20 WaterFuse House User Manual Installation Instruction...

Страница 2: ...l carefully and follow the instructions for placement and usage The product may only be connected by a qualified installer The warranty does not cover repairs of faults caused by faulty installation o...

Страница 3: ...tallation Instructions 11 2 1 General Information 11 2 2 Installation 12 2 3 Connection to house alarm system or other remote control 14 2 4 Settings 16 2 4 1 Connected units 16 2 4 2 Search for new d...

Страница 4: ...e detector but for water If they indicate water a signal is sent to the central unit which automatically shuts off the water There is also a temperature sensor in the water detectors that can be used...

Страница 5: ...ures current water pressure in the property s water system It can also be manually operated with a mechanical knob on the unit if the power goes out Lift the knob 5 mm and turn clockwise to close the...

Страница 6: ...to stay on for a limited period of time press the button delayed OFF The water stays on for the period set on the central unit where you can choose 1 4 hours The water is then turned off in the entire...

Страница 7: ...rt searching for water by the triggered water sensor Press Confirm when the fault has been rectified and the water can be turned back on Temperature Alarm If the temperature around any water sensor dr...

Страница 8: ...unication This is usually because something has changed in the home since the last time the radio communication was functioning It could for example be because there are too many metal containers unde...

Страница 9: ...y This allows your dishwasher or washing machine programme to finish even if you leave Can be set to 1 4 hours with 2 hours as the standard 2 Start Water OFF or RESET When the unit is started for exam...

Страница 10: ...it must be remedied by the user or by a plumber If you are unable to locate the lead contact your plumber for troubleshooting Tips for troubleshooting Water faucets The check is most easily conducted...

Страница 11: ...erence measure when the ball valve has closed after the user has turned the water off using the OFF delayed OFF or alarm The system then waits 15 minutes before taking the next and final measurement I...

Страница 12: ...e article number and manufacturing date 2 2 Installation Water unit The unit is intended for tap water 0 60 C and 0 10 bar Fitted after the water meter and the main water line with the motorised ball...

Страница 13: ...mote Unit art no 2220022 Place in an easily accessible place near an outer door Check so that no electrical cables or installations are found within 50 cm of the equipment as this disturbs the radio t...

Страница 14: ...stallation mode the signal strength of the transmission can easily be checked Go into menu Advanced settings and then Connected units Select unit and move down to RSSI A value lower than 60DBM is exce...

Страница 15: ...nected as follows Jumper between Pin 8 and Pin 4 Connect of the alarm to Pin 3 and of the alarm to Pin 7 In case of alarm indication Pin 3 will be 12v Digital 1 Preferably connected as follows GND One...

Страница 16: ...FF 500L Temperature limit At which temperature should the water be turned off OFF 1 2 3 4 5 degrees 3 degrees External alarm Settings for external control ON OFF 2 4 1 Connected units In order to hand...

Страница 17: ...select ON If you only want the pressure test to be conducted when the user has turned off the water select OFF 2 4 4 Volume Measurement If a water meter with a digital output port is connected to the...

Страница 18: ...them back into place The units will then start with a beep in the installation mode and transmit every 15 seconds for five minutes This makes it easier to see if the transmission effect is sufficient...

Страница 19: ...ead the operating instructions and if possible check that all settings are correct The warranty stipulates that defective parts or components will be replaced with defect free ditto The customer is re...

Страница 20: ...20 20 Tel 018 34 90 10 info tollco se www tollco se Tollco AB Rubanksgatan 4 741 71 KNIVSTA...