PLS-601 User's Manual
Document #11696 Page - 24
4.2.5 SCALE - Continued
SCALE FACTOR:
Select:
CLEAR
The value of the SCALE FACTOR is set to 1000
and entered into memory. The Control Unit
automatically returns to FUNCTION select mode
after pressing CLEAR.
New Display:
SF 1 0 0 0 P 0 7 5 - R 0 4 0
Select:
<
CURSOR
Moves the cursor left within the four digit SCALE
FACTOR data field of the front panel display.
New Display:
SF 1 0 0
0
P 0 7 5 - R 0 4 0
Select:
>
CURSOR
Moves the cursor right within the four digit SCALE
FACTOR data field of the front panel display.
New Display:
SF
1
0 0 0 P 0 7 5 - R 0 4 0
Select:
ENTER
Stores the new OFFSET value into memory on the
display. The Control Unit automatically returns to
FUNCTION select mode after pressing ENTER.
Select:
FUNCTION:
Pressing the FUNCTION key at any time while in
SCALE mode will terminates the SCALE function
and returns the user to FUNCTION select mode where
any one of the PLS-601 other functions can be selected.
4.2.6 MOTION
MOTION WINDOW
Motion allows the user to set a window for shaft speed, and receive an indication that the shaft
speed falls within the window via the MD (Motion Detect) LED and Motion Detect output (See
section 3.2.5).
The window is defined by the MOTION FROM (MF) and MOTION TO (MT) values are
considered to be WITHIN the window.
Note: If the ‘MF’ field is less than the ‘MT’ field, the MD LED and output will be ON when the
shaft speed is within the MD window, and OFF when it is outside of the window.
If the ‘MF’ field is greater than the ‘MT’ field, the MD LED and output will be OFF when the
shaft speed is within the MD window, and ON when it is outside of the window.