4.9 Parameter instructions
- shaded areas indicate default settings
.
[1--] CONFIGURATION Settings
[1-1] Measuring Unit
Value
Description
m
Sets display in Metric units
ft
Sets display in Feet units
Note: When ‘Measuring Unit’ is changed, units of other parameters also change.
[1-2] G parameter
(
distance between flange reference point and measuring reference point
)
Parameter
Default Value
Description
-3.000-3.000
0.000
R+C-G
≦
20
(Parameter range in metric [m] units)
If measurement unit is [ft], display will be converted to show ‘feet’ units.
[1-3] R parameter
(
Measurement range
)
Parameter
Default Value
Description
0.000-13.000
10.000
R+C-G
≦
10
(Parameter range in metric [m] units)
If measurement unit is [ft], display will be converted to show ‘feet’ units.
[1-4] C parameter
(
Below measurement range
)
Parameter
Default Value
Description
0.000-10.000
0.000
R+C-G
≦
10
(Parameter range in metric [m] units)
If measurement unit is [ft], display will be converted to show ‘feet’ units.
[1-5] H parameter
(
Deadband
)
Parameter
Default Value
Description
0.000-13.000
0.000
Parameter range in metric [m] units
If measurement unit is [ft], display will be converted to show ‘feet’ units