11
8-3. Camera rear-panel DIP SW and Manual GAIN adjustment potentiometer
(1) External-sync IN impedance selection
To switch the input impedance of external sync signal, open the camera chassis, and select the
position of the slide switch mounted on the bottom board (REG board).
No.
SW Function
SW Status
Selected Function
High
High impedance
1
Ex-sync input impedance SW
75
75-ohm
[NOTES]
l
The factory setting is shown with boldface underlined font.
(2) External trigger signal input polarity selection
To switch the input polarity of external trigger input, open the camera chassis, and select the
position of the slide switch mounted on the top board (PROCESS board).
No.
SW Function
SW Status
Selected Function
OFF
Positive (Rising-edge)
1
Ex-trigger signal input polarity
selection SW
ON
Negative (Falling-edge)
2
TEST
OFF
NC
[NOTES]
l
The factory setting is shown with boldface underlined font.
1
O
N
2
Ex-trigger Input
Polarity Selection
1
O
N
2
Lens-mount
PROCESS Board
Camera Connector
Lens-mount
High
75
Ex-SYNC IN Input
Impedance Switch
Содержание CS3730DC