background image

Hose connection 

WARNING 

Install the metallic cap of the air hose onto the body of the air tool firmly. The metallic cap will come off and 
cause the hose to run amuck due to vibration if the metallic cap is used in a loose condition. This will be very 
dangerous.

 

 
Check for damage of the air hose and in the connection part of the air tool body. 
Confirm that there is no dust or dirt.   
Do not point the air hose at anyone.   
Never use compressed air to clean cloth.   

 

Operation 

 

CAUTION 

Keep your feet away from the chisel. There would be a risk for injury if the chisel drops onto the operator' s foot 
when the chisel is broken.

 

 
Never operate an air tool at an air pressure over the limit of the air tool.   
Confirm that the retainer of the chisel is locked firmly before starting the air tool.   
Never start an air tool without a chisel.   
Always hold an air tool with both hands. Confirm that the handle is clean without any grease or oil.   
Do not place the air tool on a person's foot.   
Always keep well balanced during operation.   
Never get on a tool. For example, do not put one foot on the handle of the air tool.   
This may become a reason to get hurt especially when the air tool is broken.   
Investigate the material of the work. For example, when using the tool for electric and telephone cable, water 
and drain pipe, etc, inspect for hidden cable or pipe underground before operating an air tool. 
In case the chisel hits something during operation, stop the air tool immediately.   
Restart the tool after the danger is cleared.   

 

Service and maintenance 
Turn the valve cock of the compressor completely to the stop position, hold down the throttle valve and release 
the pressure in the air hose completely before disconnecting an air tool. 
Read  and  understand  the  instruction  manual  correctly.  Contact  with  the  selling  agent  or  distributor  of  the 
manufacturer for further service information if necessary.   
Whet it is necessary to use solvent to clean parts, be sure it is within the safety standards first, then use the 
solvent at a place with good ventilation. 

 
Never be careless   
Always concentrate on the work.   
Always use common sense.   
Eye vision and reaction deteriorate significantly in fatigue conditions after taking medicine, or drinking alcohol.   
Never use an air tool when you are under the influence of these conditions.   

 
Always direct exhaust away from yourself and others in the aria. 

 
Always disconnect tool from the air supply when not in operation.   
If quick-disconnect couplings are used, separate the coupling from the tool with a leader hose. 

 
Always make sure cutting chisel is securely latched in the tool before depressing throttle trigger. 

 
Always hold cutting tool down firmly on the work before depressing throttle trigger. 
 

 

 

[email protected]

Air & Allied Sales (Pacific) Pty Ltd

www.air-allied.com.au

Содержание AIR & ALLIED SALES TJ-15

Страница 1: ...RD GIVE TO USER Do not use a Rack Drill until this safety instruction has been read and understood completely This manual is necessary to help you to use the Rock Drill correctly WARNING Do not use a Rock Drill before reading this safety instruction manual Obey all of the safety measures indicated in this manual FOR DETAILED INFORMATION ABOUT TOKU AIR TOOLS AND EQUIPMENT CONTACT TO Air Allied Sale...

Страница 2: ...ool The manufacturer will not assume any responsibility concerning an accident resulting in injury death or any trouble from an air tool due to the reconstruction without the permission of the manufacturer Always use GENUlNE tool replacement parts recommended by the manufacturer when replacing any part of an air tool There must be a sticker or a sign indicating matters concerning the safety precau...

Страница 3: ...ipe etc inspect for hidden cable or pipe underground before operating an air tool In case the chisel hits something during operation stop the air tool immediately Restart the tool after the danger is cleared Service and maintenance Turn the valve cock of the compressor completely to the stop position hold down the throttle valve and release the pressure in the air hose completely before disconnect...

Страница 4: ...d working shoes are worn correctly Air Supply Whether the air pressure is suitable For best operation supply tool with 90psig 6 2bar of clean dry air Higher pressure drastically reduces tool life and can void warranty 600kPa for max Lubrication To flush out GUM and DIRT you should do the following two steps EACH DAY 1 Before the shift pour a liberal quantity of gum solvent oil into the tool s air ...

Страница 5: ...for a Rock Drill Clean the exterior surface using a cloth Regularly inspect the tightening torque on the bolts Inspect whether there are any cracks or damage in the Rock Drill Storage of the Rock Drill Apply 3 cc of oil from the air inlet operate the Rock Drill for about 5 seconds after completing work Repeat above operation 2 3 times before storing the Rock Drill Put a cap on the air inlet of the...

Страница 6: ...off air hole in Line Oiler tank Correct Line Oiler position is shown on picture A below Hose in the Line Oiler must be downside when placing the Rock Drill horizontally on the ground as position shown below picture Air consumption at air pressure of 600kPa 1 6 m3 min Sound levels with muffler ISO 15744 Sound pressure level LpA 110 74 dB A Uncertainty KpA KWA Sound power level LWA 121 74 dB A 3 dB ...

Страница 7: ...g between Cylinder Upper Flange and Exhaust hole Flange Reassemble Parts and tighten Through Bolt Nuts equally Tightening Torque 5 8kgf m 56 9N m Put Muffler onto Rock Drill Muffler Groove and Muffler Bushing must correspond Tighten Screws and Nuts 6 Points tightening Torque 29kgf cm 3N m Exhaust Side Holes For Through Bolts 7 sales air allied com au Air Allied Sales Pacific Pty Ltd www air allied...

Страница 8: ...roduct s ROCK DRILL 5 Model Type TJ 15 6 Version s TJ 15 PFF15 PK 140 LS J 15 TJ 15SV PFF15SV PK 140 SA J 15SV 7 Starting Serial No 11J001 8 is in conformity with the requirement of the council Directives on the approximation of the laws of the Member States relating 9 to Machinery 2006 42 EC 10 applicable harmonized standard s EN ISO 12100 11 Place and date Saga Japan 03 10 2011 12 NAME and POSIT...

Страница 9: ...partono dul suffiss 8 è sono in conformità con le esigenze previste dalla Direttiva del Consiglio sulle legislazioni degli Stati membri relative 9 alle macchine 2006 42 CE 10 norma e armonizzat e applicabile i 11 NOME e FUNZIONE del dichiarante 12 Data PORTUGUÊS PORTUGUESE 1 DECLARAÇÃO DE CONFORMIDADE CE 2 Nós TOKU 3 Ficheiro técnico disponivel na 4 declaramos que o produto Martelo Perfurador 5 ti...

Страница 10: ...TJ 15 Parts List Exploded View 13th edition 10 sales air allied com au Air Allied Sales Pacific Pty Ltd www air allied com au www air allied com au ...

Страница 11: ... Grip Pipe X 18 430101C80 1 Cylinder X 19 430101P60 1 Exhaust Cap A 20 430101F80 1 Valve X 21 430101F9B 1 Valve Chest CP X 22 430101G20 1 Valve Guide X 23 130403001 1 Valve Knock X 24 430101G60 1 Ratchet X 25 130409001 1 Ratchet Key A 26 430101H01 1 Rifle Bar X 27 430101H10 1 Rifle Nut X 28 430101E50 1 Piston X 29A 430101H20 4 Rotation Pawl X 29B 136303002 4 Pawl Plunger X 30 130803006 4 Pawl Plun...

Страница 12: ...Location of Serial number Year of manufacture and Name plate 12 sales air allied com au Air Allied Sales Pacific Pty Ltd www air allied com au ...

Отзывы: