TOKISTAR LIGHTING
1015 E. Discovery Lane
Anaheim, CA 92801
TEL: 714 772 7005 FAX: 714 772 7014
email: [email protected] Website: tokistar.com
Advantage Series
PRECAUTIONS
1. Read all instructions completely before beginning installation.
2. Turn off electricity before beginning installation.
3. All wiring is to be performed by a qualified electrician.
4. Installation must comply with the National Electrical Code, and all applicable codes.
5. Turn main supply to transformer on only after all connections are made and tested.
6. Use only transformers provided by Tokistar with the system.
General Description
Tokistar’s Advantage Series is a 24 VAC lighting system using LED modules or rigid-loop xenon lamps. LEDs are
0.72 watts. Xenon lamps are available at 3 watt and 5 watt. Xenon lamps have the voltage and rating stamped on the
glass at one end. Each Advantage fixture is labeled with wattage and operating voltage.
This chart gives recommended
maximum lengths which take into
account these two limitations.
Conforming to these lengths will
ensure no fixture exceeds 480
Watts, and will not be subjected to
excessive voltage drop.
Secondary Circuit Limitation
The maximum load of each fixture must not exceed 480
Watts (20 amps @ 24 Volts). In addition to this limitation,
consideration must be given to the effects of voltage drop.
Fixtures with lower wattage lamps (such as LEDs) and
more distant socket spacing have recommended maximum
lengths less than 480 Watts.
Secondary Circuit Limitation
Each secondary circuit MUST NOT exceed
20 amps (480 watts @ 24VAC)
T
T O K I S TA R L I G H T I N G
I N S T R U C T I O N M A N U A L
END VIEW
Socket
Wire
Wire
Side View
24/5
LED
Module
The voltage and lamp rating are stamped
on one end of the xenon lamps.
END VIEW
Wire
Socket
Side View
Wire
END VIEW
Xenon Lamp
Light Source
Description
Part No.
0.72 Watt LED
0.72 Watt LED
0.72 Watt LED
0.72 Watt LED
3 Watt Xenon
5 Watt Xenon
AVLED-KC
AVLED-LW
AVLED-WW
AVLED-IW
XB-3F
XB-5F
3 Watt/X3
5 Watt/X5
0.72 Watt LED Modules
Maximum Lamps/Circuit
160 Lamps
96 Lamps
400 LEDs
Lamp Spacing
Maximum Run Lengths
2.4" O.C. (60 mm)
3" O.C. (75 mm)
4" O.C. (100 mm)
6" O.C. (150 mm)
32' (9.6 M)
40' (12 M)
48' (14.4 M)
60' (18 M)
19' (5.76 M)
24' (7.2 M)
32' (9.6 M)
48' (14.4 M)
80' (24 M)
100' (30 M)
133' (40 M)
200' (60 M)
Version 1.1