Orifice
Flex Replacing the Tip Body
Attentions
①Remove the nozzle, orifice, insulator and
plastic cap in order.
②Hold the torch body with a wrench and remove
the tip body by turning it counterclockwise with
another wrench.
③When replacing the tip body, be
sure to hold the torch body with a
wrench as well as removal proce-
dure and tighten the tip body and
put the plastic cap back.
④Whenever attaching or detaching the tip body always be
sure to hold the torch body with a wrench. After securely
tightening the tip body screw on the plastic cap.
Insulator
Nozzle
Plastic Cap
Plastic Cap
■
TL-35F
Tighten Securely
Tip Body
Tip Body
Torch Body
Plastic Cap
Tip
Tip Body
Torch Body
Replacing the Tip Body
If damaged by heat or spatter please unscrew the tip body using a
wrench and replace with a new one.
NOTICE: To avoid excess heat generation and unstable
arc please be sure to always tighten the tip body
securely.
When removing the tip body from
a flexible torch body be careful
not to damage the plastic cap.
ライナ
Replacing the Liner
For Tokin Connection
If wire feeding becomes unsteady due to liner wear or is clogged with wire
shavings, rust or dirt, please replace the liner by the following procedure.
Electric Connector
Electric Connector
Liner Nut
Torch Adapter
Liner
①
Place the cable in a straight line.
②Unscrew the liner nut. Rotate the torch end counterclockwise
until the liner fitting can be easily grasped. Pull out the liner.
File off any burred edges.
③Fully insert the new liner into the cable. Measure the length L which protrudes
from the end. Pull the liner out and cut off the same length L from the front.
After cutting, file off any burred edges. A long liner will cause gas leaks, whereas
a short liner will disrupt wire feeding.
Liner O-Ring
Without twisting carefully insert the length-adjusted liner into the cable.
④Without twisting carefully insert the length-adjusted liner into the cable.
Because the O-ring at the front of the liner fitting prevents gas leaks, please
be careful when measuring For Direct Connection.
Liner Nut
Liner
After setting the liner as illustrated, tighten the liner nut by hand.
Hand-tightening will be enough. Do not use a wrench, pliers, or other
tools.
For Direct Connection
①Place the cable in a straight line.
②Using a hexagon wrench loosen the set
screw on the electric supply fitting. Rotate the
torch end counterclockwise until the liner
fitting can be easily grasped. Pull out the liner.
④Without twisting carefully insert the length-ad-
justed liner into the cable. Because the O-ring
at the front of the liner fitting prevents gas
leaks, please be careful when measuring. A
long liner will cause gas leaks, whereas a
short liner will disrupt wire feeding. Using a
hexagon wrench tighten the set screw on the
electric supply fitting.
③Fully insert the new liner into the cable. Measure
the length L which protrudes from the end. Pull
the liner out and cut off the same length L from
the front. After cutting, file off any burred edges.
Hexagon
Wrench
Liner
Liner
Liner O-Ring
Liner
Cutting Position
6
Содержание TokinArc TL Series
Страница 10: ...MEMO 9...
Страница 11: ...MEMO 10...