![Tokheim TQM Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/tokheim/tqm/tqm_manual_1124944028.webp)
Page 3-8
Document Ref 942175-001 Rev 3
TQM Meter for Fuel Dispensers
Component Technical Manual
3.7
Metrological Adjustment
The scale is based upon 100% of the metering gauge.
The deviation (+ and -) is related to the calculator display.
-
+
99.40
100.50
100.60
99.50
99.60
99.80
99.70
100%
99.90
100.20
100.10
100.40
100.30
Check the piston meter
(refer to section 4.2)
Adjust piston meter by turning both
adjustment screws in direction "-"
(counter clockwise).
Example:
If the deviation is +0.3% then turn
each
adjustment screw by 3
graduations to "-"
Adjust piston meter by turning both
adjustment screws in direction "+"
(clockwise).
Example:
If the deviation is -0.3% then turn
each
adjustment screw by 3
graduations to "+"
Check the piston meter
(refer to section 4.2)