5
4. Terms and Functional Description
4.1 Set the Number of Patterns
- The maximum number of steps are determined depending on the number of patterns.
- The relationship between the number of patterns and the maximum number of steps is as shown in the table below.
Number of Patterns
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
Maximum number of Steps
64
32 21 16 12 10
9
8
7
6
5
5
4
4
4
4.2 Event Output 1 / Event Output 2
1. Deviation upper/lower limit
5. Absolute value upper/lower limit
ALd
SV
ALd
ALL
ALH
△
0
°C
ALd
ALd
ALL
ALH
2. Deviation upper limit
6. Absolute value upper limit
SV
ALd
ALH
△
0
°C
ALd
ALH
3. Deviation lower limit
7. Absolute value lower limit
ALd
SV
ALL
△
0
°C
ALd
ALL
4. Deviation upper/lower limit range
8. Absolute value upper/lower limit range
ALd
SV
ALL
ALH
△
ALd
ALd
ALd
0
°C
ALL
ALH
: Temperature Event Output operation range ALL: Event Output lower limit setting ALH: Event Output upper limit setting
ALd: Event Output sensitivity