background image

     

 5 

 

9 .     D i m e n s i o n a l   O u t l i n e   D r a w i n g  

 

     

 

Fig. 1 Dimensional Outline Drawing (Cable Type ; Figure Shown Is the S type)  

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 2 Dimensional Outline Drawing (Probe Type ; Figure Shown Is the L type)  

 
 

50mm

3

5

m

m

50mm

460mm

40mm

38mm

M 4

×

M 4

×

( 白 )

55

25

φ

1

4

2000mm

3

8

m

m

セ ン サ 保 護 キ ャ ッ プ

湿 度 セ ン サ 素 子

T I - A

温 度 セ ン サ 素 子

P t 1 0 0

H u m i d i t y   S e n s o r   E l e m e n t   T I - A  

T e m p e r a t u r e   S e n s o r   E l e m e n t   P t 1 0 0  

S e n s o r   P r o t e c t i v e   C a p  

S e n s o r   P r o t e c t i v e   C a p  

( F o r   v o l t a g e  
o u t p u t   o n l y )  

B l a c k  

G r e e n  

P u r p l e  

B l u e  

Y e l l o w  

B r o w n  

B l a c k  

G r e e n  

P u r p l e  

B l u e  

Y e l l o w  

B r o w n  

( W h i t e )  

3

8mm

 

3 8 m m  

Содержание TSM-H2

Страница 1: ...n 2 2 Structure and Method of Connection 2 3 Specifications 2 4 Chemical Resistance 3 5 Things to Be Noted in Handling the Product 3 6 Replacement of Sensor 3 7 Warranty Period 4 8 Disclaimer 4 9 D i...

Страница 2: ...are the following Usable Temperature Range Main Unit 5 to 55 Sensor Section 25 to 100 Measuring Humidity Range 0 to 100 RH Measuring Accuracy at 25 For TSM H2 2 RH 10 to 90 RH 3 RH 2 to 10 RH 90 to 10...

Страница 3: ...or a long time 3 Do not soak the product in water 4 Do not touch the sensor element directly with your hand Use tweezers to attach remove the sensor element Be careful not to damage the sensor element...

Страница 4: ...ent See the Warranty Period of Humidity Sensor Element TI A for the sensor section We will repair the product free of charge for any trouble due to our fault within this period However please be noted...

Страница 5: ...L type 50mm 3 5 m m 50mm 460mm 40mm 38mm 55 25 1 4 2000mm 3 8 m m Hum i di ty Se n sor E l em en t T I A T em per a tur e S en s or E lem e n t P t 10 0 Se n so r Pr o tec ti ve Ca p Se n so r Pr o te...

Страница 6: ...tline Drawing Duct Type Rubber Packing Main Unit M4 Countersunk Screw 40mm or pan head tapping screw Drilling location for duct etc Two positions If the tapping screw is used the hole diameter depends...

Страница 7: ...t TSM H2 H3 20120301 1 DC 9 25V I mA V For Voltage Output For Current Output Blac k B G ree n b Fo r tem per a tur e s en s or elem en t Y ello w A Pur ple Bl u e DC P owe r C on tr olle r etc Blac k...

Отзывы: