Tohnichi WQL Series Скачать руководство пользователя страница 5

6. OPERATING PROCEDURE 

 

1)  

Set the desired snug torque. 

2)  

Connect the flexible tube to the pointer adapter and fix the clip to the work piece or the bolt nearby.       

3)  

Engage the socket with a bolt. 

4)  

To preset angle:   

Set the pointer to the desired angle and start tightening.    After the snug torque is reached, the angle scale 

starts moving.      Tighten the bolt until the angle scale reads zero degree. 

5)  

To read angle: 

Set the pointer to zero degree on the angle scale.    After the snug torque is reached, the angle scale starts 

moving.    Tighten the bolt until the desired torque is reached.   

6)    To use the wrench as an ordinary torque wrench: 

Remove the flexible tube from the pointer adapter and set the desired torque.    Tighten the bolt until a 

click

 is heard. 

7)    To attach a magnet base: 

Remove the nut that fixes the clip and flexible tube.    Insert the top screw (M8X1.25) of the flexible tube 

into the screw hole in the magnetic base and tighten. 

Note:    Recommended magnetic base is Kanetsu MB-PB or    Fuji Jiko BR-50. 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5