INSPECTION AND MAINTENANCE
74
10
*"
z
" This procedure can be performed by end user.
*"
{
" This procedure shall be carried out by the dealer.
ENON00030-1
Note
It is highly recommended that your outboard motor to go through complete inspection at 300
hours of use.
Lower Unit
Propeller
z
z
Check/Replace if necessary.
Shear pin/Split
pin
z
z
Check/Replace if necessary.
Gear oil
z
Replace
z
z
Replace
Change and replace.
Approx. 460 mL
(15.6/16.2 US/
Imp. oz.)
Water strainer
z
z
Check
Water pump
impeller
z
/
{
{
Replace
Check/Replace if necessary.
Water pump
housing
{
Check/Replace if necessary.
Shift/
Throttle
Throttle cable
{
Check/Replace if necessary.
Throttle link
{
{
Check and adjust.
Shift cable
{
Check/Replace if necessary.
Shift link
{
{
Check and adjust.
Power trim & tilt
z
/
{
z
/
{
Check and replenish.
Warning system
{
Check
Stop switch
z
z
Check
Meters
{
{
Check
Bolt, nut
{
{
Retighten
Sliding part/rotation part
z
z
Apply grease and Pump in
grease
Grease nipple
z
z
Pump in grease
Outer equipment
z
z
Check
Anode (engine)
{
Check/Replace if necessary.
Anode (except for engine)
z
/
{
Check/Replace if necessary.
Top cowl/Ratch
z
/
{
Check and adjust.
Description
Inspection intervals
Inspection procedure
Remarks
First 20
hours or 1
month
Every 50
hours or 3
months
Every 100
hours or 6
months
Every 200
hours or 1
year
Every 400
hours or 2
year