![Toggle TOGL2448EL Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/toggle/togl2448el/togl2448el_assembly-instructions-manual_1124531003.webp)
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
3
Toggle
®
Tables - Dual Motor Height Adjustable Base, Model EL
Assembly Instructions
Table Wiring
Note:
Control cables can be routed
differently than shown. 24” deep
tables must have the control box
mounted between the cross-tube
assemblies, which requires
installation of the “optional key pad”
(Figure 4). All 30” & 36” tables may
have the control box mounted either
between the cross-tube assemblies,
at one of the two locations behind
the cross-tube assemblies or one of
two locations at the front of the table
(Detail A). Mounting to the front of
the table does not require the use
of the “optional key pad”. Follow
directions appropriate to control box
mounting location.
Note:
When plugging leg control
cord ends in, make sure to push in
straight to avoid bending any pins
in the electrical control box or leg
motor. The plug will click when it is
locked into place.
Note:
If any plug needs to be
removed, make sure power cord
is un-plugged from power source
outlet first. Then push down
on release tab on the control
cable plug while simultaneously
pulling on the end to remove
from the socket.
1.
Leg Cord - Long:
Plug the
longer leg control cord into one
of the two rectangular sockets on
the control box, then route cord
to the leg farthest from control
box. Use cut outs in the table
to route under the cross tubes
and/or use zip ties secured with
screws at pre-drilled locations.
Plug other end of the longer leg
control cord into the open socket
on leg motor (Figure 4).
2.
Leg Cord - Short:
The next
rectangular socket on the control
box is utilized by the shorter leg
control cord. Plug short leg cord
into control box and route to the
leg motor socket that is closest
to the control box. Use cut outs
in table to route under the cross
tubes. Plug other end of the
shorter leg control cord into open
socket on leg motor (Figure 4).
3.
Optional
Key Pad:
The key pad
can be mounted on the front side
of table top (Figure 4). Using
pre-drilled holes, secure key pad
to table top with two M4.2 x 19
flat head screws at 1.5 ft/lbs.
Note:
Do not overtighten screws.
Once key pad is mounted, route
attached cord to control box. Use
Figure 4 for cord routing reference
and for the optimal usage of
zip-tie points. Once the key pad
cord is routed to control box, plug
cord into the round socket on box
(Figure 4).
Note:
Make sure all cables are
routed correctly and plugged into
correct sockets on control box
and leg motor locations before
installing zip-ties.
4.
Zip-ties:
Six zip-ties are included
for keeping cords tight to table,
but it is not necessary to use all
six. Using Figure 4 for reference,
wrap the zip-ties around the loose
cords and then mount the zip-tie
to the table top with a M5.5 x 22
pan head screw into the
pre-drilled holes. The zip-ties
have a built in mounting hole
which must lay flat onto surface.
Make sure zip-ties and cables are
snug before moving to next step.
5.
Power Cord:
The final cord to
be installed is the power cord.
Plug power cord into remaining
open socket which is tri-lobe in
shape. Cord should not be
zip-tied or routed through cut outs
on table (Figure 4). Do not plug it
into power source at this time.
6. If optional wire trough was
specified for installation, go now
to page 4. If no wire trough is
specified, carefully turn table to
the upright position with the help
of another person. Adjust glides
on feet to level the table. Plug the
power cord into a grounded outlet
power source (Detail C).
Note:
Power cord must have enough
slack so the table can cycle
through its entire range of motion.
7.
The table must be “zero set”
prior to being placed into
service. Refer to table “zero
setting” instructions in the
trouble shooting guide on
page 6.
8. If the table is not operating
properly, see the trouble shooting
guide in this instruction.
Toggle Tables - Electric Base
Assembly Instructions
Table Wiring
Note:
Control cables can be routed
differently than shown. Illustration is for
reference only (Figure 3).
Note:
When plugging leg control cord
ends in, make sure to push in straight to
avoid bending any pins in the electrical
control box or leg motor. The plug will
click when it is locked into place.
Note:
If plug needs to be removed,
make sure power cord is un-plugged
from power source outlet first. Then
push down on release tab on the
control cable plug while simultaneously
pulling on the end to remove from the
socket.
1.
: Plug the longer leg
Long Leg Cord
control cord into outer most hole
labeled “
1” on control box. Then
LA
route cord to leg farthest from control
box. Use cut outs in table to route under
cross tubes. Plug other end into open
hole on leg motor (Figure 3).
2.
The next hole to
Short Leg Cord:
the right on the control box will be
utilized by the shorter leg control
cord. Plug short leg cord into control
box at the hole labeled “
2” and
LA
route to the leg motor socket that is
closest to the control box. Use cut
outs in table to route under the cross
tubes. Plug other end into open hole
on leg motor
(Figure 3).
3.
The key pad can be
Key Pad:
mounted in two locations. Both
locations are on the front side of
table top and opposite of electronic
control box (Figure 3). Using pre-
drilled holes, secure key pad to table
top with
M4.2 x 19 flat head screws. Once
key pad is mounted, route attached
cord to control box. Use Figure 3 for
cord routing reference and for the
optimal usage of zip tie points. Once
the key pad cord is routed to control
box, plug cord into the smallest hole
on box labeled “
” (Figure 3).
RC
Note:
Make sure all cables are routed
correctly and plugged into correct
holes on control box and leg motor
locations before installing zip-ties.
4. Zip-ties:
Included are four zip-ties
for use to keep cords tight to table.
Using Figure 3 for reference, wrap
the zip ties around the loose cords
and then mount the zip-tie to the
table top with a M5.5 x 22 pan head
screw into the pre-drilled holes. The
zip-ties have a built in mounting hole
which has to lay flat onto surface.
Make sure zip-ties and cables are
snug before moving to next step
5.
The final cord
Power Cord:
installed is the power cord. Plug
power cord into remaining open hole
which is elevated higher on the
control box then the rest. This hole is
labeled “
110-120V”. Cord should
AC
not be zip-tied or routed through cut
outs on table (Figure 3). Do not plug
in into power source at this time.
6. With two people, carefully turn
table to the upright position. Adjust
glides on feet to get table level. Plug
Power cord into power source and
test the height adjustable table. If
table is experiencing issues see the
trouble shooting guide in this
instruction.
M4.2 x 19
flat head screw
M5.5 x 22
pan head screws
leg control cord
(long)
leg control cord
(short)
power
cord
Detail B - 30 & 36 Table with Front Control Box
"
"
Figure 4
leg control cord
(long)
key pad
cord
leg control cord
(short)
power
cord
key pad
(optional)
leg motor
control
box
control
box
M4.2 x 19
flat head screw
(max torque is 1.5 ft/lbs)
M5.5 x 22
pan head screws
(six)
zip-ties
(six)
cross-tube
assembly
This product is for use on a nominal 120-volt circuit and has a grounding plug
that looks like the plug illustrated in Detail C. Make sure that the product is
connected to an outlet having the same configuration as the plug. No adapter
should be used with this product.
Detail C
grounding
pin
grounded
outlet
GROUNDING INSTRUCTIONS