OM-189 507 Page 7
3-2.
Remote 14 Receptacle RC14 Information And Connection
sb7.1* 3/93 - Ref. S-0004-A / Ref. S-0750 / Ref. 802 663
1
Plug
2
Threaded Collar
3
Keyway
4
Remote 14 Receptacle RC14
(See Section 3-3)
To connect to receptacle, align key-
way, insert plug, and tighten
threaded collar.
1
2
4
A
J
B
K
I
C L N
H
D
M
G
E
F
3
4
3-3.
Remote 14 Socket Information
Socket
Socket Information
A
+24 volts dc.
Contactor
A
B
+24 volts dc.
Contact closure to A completes 24 volts dc contactor control circuit.
C
Command reference; +10 volts dc.
Remote
C
D
Command reference; +10 volts dc.
Control circuit common.
A
J
B
K
I
Output
Control
D
E
Control circuit common.
Input command signal (potentiometer wiper or 0 to +10 volts dc).
B
I
L
N
H
Control
E
G
Input command signal (potentiometer wiper or 0 to +10 volts dc).
Not used.
4
C
L
N
H
D
M
G
E
F
Power
Source
Fault
F,J
Absence of internal contact closure between F and J signals power source failu-
re to remote control device.
H
Coil loss compensation value.
H
I
Coil loss compensation value.
Actual frequency output signal (1 volt/5 kHz).
Remote
I
L
Actual frequency output signal (1 volt/5 kHz).
Average power output signal (1 volt/1 kW).
Remote
Metering
L
M
Average power output signal (1 volt/1 kW).
Voltage output signal RMS (1 volt/50 volts).
N
Current output signal RMS (1 volt/50 amperes).
K
Chassis common.
Содержание TOCCOtron AC
Страница 2: ......
Страница 4: ......
Страница 22: ...OM 189 507 Page 18 SECTION 6 ELECTRICAL DIAGRAM Figure 6 1 Circuit Diagram For Induction Heating Power Source...
Страница 23: ...OM 189 507 Page 19 199 924 A...