Control panel

mounting screws

II. INSTALLATION

IMPORTANT

IT  IS  THE  CUSTOMER’S  RESPONSIBILITY  TO  REPORT  ANY

CONCEALED OR NON-CONCEALED DAMAGE TO THE FREIGHT

COMPANY.

A. Installation Options and Kit Availability

Your hot food server is shipped from the factory with 4” NSF-listed

plastic legs, which may be used on single-unit or two-stack installa-

tions.  The following kits are available from Toastmaster for additional

installation options:
•

P/N ACCHFSC

Casters kit (for 1-4 units)

•

P/N ACCHFS6

6” legs kit (for 1-4 units)

•

P/N ACCHFS9

9” legs kit (for 1-4 units)

All hot food server installations REQUIRE the unit(s) to be mounted

on legs or casters prior to operation.  The allowed installation configu-

rations are:

Supplied

Casters

6” legs

9” legs

4” legs

kitkitkit

Single unit

YES

YES

YES

YES

Two-stack

YES

YES

YES

YES

Three-stack

NO

YES

YES

YES

Four-stack

NO

YES

YES

YES

CAUTION

STACKING MORE THAN FOUR SERVERS IS NOT PERMITTED.

B. Legs/Casters Assembly

1.

To install the supplied 4”/102mm legs (1-2 units only), thread the

legs into the four holes on the bottom of the hot food server.  An

illustration of the server with the supplied legs installed is shown

on the cover of this Manual.  For a Two-Stack installation, attach

the legs to the bottom server only.

2.

To install an optional Legs Kit or Casters Kit, refer to the instruc-

tions provided with the Kit.

C. Stacking the Hot Food Servers (2-4 units only)
CAUTION

If you have installed the optional Casters Kit, check that the casters

are locked before stacking the hot food servers.

Perform  the  following  steps, starting  with  the  server  that  has  legs/

casters installed:
1.

Remove the two screws that hold the control panel in place.  Be

sure to retain the screws.  See Figure 2.

2.

Gently pull the control panel out from the front of the unit and

allow it to hang by the wiring.  DO NOT stretch or disconnect the

wiring!  See Figure 2.

3.

Remove the cap plug from the top panel of the unit.  To remove

the plug, bend the tines on the underside of the plug in towards

the center using a pair of pliers.  Then, lift the cap free and dis-

card it.  See Figure 3.

4.

Place a hot food server atop the unit.  Check that all four sides of

the units are aligned.

5.

Attach the two units together by inserting the supplied 3/8” bolt

from inside the control panel opening of the lower server, as shown

in Figure 4.  The bolt passes through the hole in the top panel

and into the threaded leg hole in the floor of the upper unit.  Tighten

the bolt to a LOOSE fit to allow the position of the units to be

adjusted.

6.

At the rear of the upper server, remove the screws from BOTH

bottom rear corners, as shown in Figure 4.  Then, loosen (do not

remove) the two screws on the lower server that hold the stack-

ing clips in place.

7.

Reposition the stacking clips as shown in Figure 4, and replace

the  two  screws  that  you  removed  in  Step  6.   Tighten  all  four

screws.

8.

Tighten the 3/8” bolt (that you installed in Step 5) to secure the

units together.

9.

Replace the control panel, and fasten it in place with its screws.

10. Repeat Steps 1-9 until all units are stacked.  Note that the cap

plug will remain in place on the top server in the stack.

D. Electrical Connection
IMPORTANT

THE  ELECTRICAL  CONNECTION  TO  THE  HOT  FOOD  SERVER

REQUIRES A CIRCUIT BREAKER/FUSED DISCONNECT.  ELEC-

TRICAL SPECIFICATIONS ARE  LISTED ON THE SERIAL PLATE

(SHOWN IN FIGURE 4), AND IN SECTION I OF THIS MANUAL.
CONSULT ALL APPLICABLE NATIONAL AND LOCAL CODES FOR

FURTHER ELECTRICAL CONNECTION REQUIREMENTS.

1.

Before proceeding with the electrical connection, check the fol-

lowing for each hot food server:
a.

Check  that  the  electrical  supply  matches  the  hot  food

server’s requirements.  Refer to the serial plate (Figure 4)

and to the electrical specifications shown in Section 1 of

this Manual.

b.

Check that the appropriate receptacle is available for the

power cord plug.

WARNING

ENSURE THAT BOTH THE CIRCUIT BREAKER/FUSED DIS-

CONNECT AND THE POWER ON/OFF (I/O) SWITCH ARE

IN THE 

OFF

 (“O”) POSITION BEFORE PROCEEDING.

WARNING

ENSURE THAT ANY PACKING MATERIAL HAS BEEN RE-

MOVED FROM INSIDE THE CABINET AND FOOD TRAY.

3.

Insert (each) power cord plug into its receptacle.

Figure 2

Figure 3

2. To remove,

bend tines in

towards

center of plug

1. Cap plug

shown

in place

3. After stacking,

insert bolt

through cap hole

Figure 4 (left side shown - reposition brackets on BOTH sides)

Underside

of server

Control

panel

opened

Data plate

1. Remove

2. Loosen

3. Reposition

4. Replace

5. Tighten

Отзывы: