WARNING 

CAUTION 

1.  SAFETY PRECAUTIONS 

  Be sure to read the instructions in this section carefully before use. 

  Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as 

very important precautions are included. 

  We also recommend you keep this instruction manual handy for future reference. 

 

Indicates a potentially hazardous situation which, if mishandled, could 

result in death or serious personal injury.

To prevent the electromagnetic wave from badly influencing medical equipment, 
make sure to switch off the unit's power when placing it in close proximity to the 
medical equipment. 

 

Prohibited

 

Indicates a potentially hazardous situation which, if mishandled, could 

result in moderate or minor personal injury, and/or property damage. 

 

  When the unit is not in use for 10 days or more, be sure to take the battery out of the unit because 

battery leakage may cause personal injury or contamination of environment. 

  Make sure to observe the following handling precautions so that a fire or personal injury does not 

result from leakage or explosion of the battery. 

· Do not short, disassemble heat nor put the battery into a fire. 

· Do not solder a battery directly. 

· Be sure to use the specified type of battery. 

· Note correct polarity (positive and negative orientation) when inserting a battery in the unit. 

· Avoid locations exposed to the direct sunlight, high temperature and high humidity when storing 

batteries. 

  When the battery becomes inflated or leaks, discontinue use and replace with new one immediately. 

 

CAUTION TO USER

: Changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment. 

 

 
 
 
 

Compulsory 

Содержание WM-5420

Страница 1: ...SWITCH FUNCTION AND USAGE METHOD 7 10 TALK SWITCH SETTING 8 11 CHIME SETTING 8 12 MICROPHONE SENSITIVITY SETTING 9 13 WHEN USING EXTERNAL MICROPHONE 9 14 USING POCKET CLIP 10 15 TROUBLESHOOTING 11 16...

Страница 2: ...ury and or property damage When the unit is not in use for 10 days or more be sure to take the battery out of the unit because battery leakage may cause personal injury or contamination of environment...

Страница 3: ...e unit to rain or an environment where it may be splashed by water or other liquids as doing so may result in unit failure Never open nor remove the unit case to modify the unit Refer all servicing to...

Страница 4: ...green LED starts to dim while the red LED to light The microphone does not transmit the signal if the channel selector switch is set to the empty channel In this case the red LED and green LED flash...

Страница 5: ...ery compartment BASIC USAGE When the unit is purchased in its new condition refer to table on the right it may be used once battery is inserted and the group number and channel number set 6 BATTERY IN...

Страница 6: ...e A B switch function set A and B to the same channel Step4 Replace the battery cover 8 OPERATION Step1 Confirm that the wireless microphone and the wireless tuner are identical in the channel number...

Страница 7: ...be used in two different ways The following may be configured differently for mode A and mode B Channel number Talk switch option Chime option Microphone sensitivity option All other settings except...

Страница 8: ...mode Note Setting should be done when talk switch is off If talk switch is on the setting will not change LOCK OFF ON Talk switch setting Default setting is off Inside battery cover LOCK OFF Disable...

Страница 9: ...one can be available Refer to the microphone sensitivity setting SETTING EXTERNAL MICROPHONE The optional microphone YP M201 has the talk switch This can be available to turn on off WM 5420 Select ext...

Страница 10: ...e external microphone function is set to on WM 5420 will sometimes turn on when the external microphone is being plugged or unplugged Check if WM 5420 is on off using Power Battery lamps when plugging...

Страница 11: ...eration may cause the chime to repeat continuously 16 FREQUENCY TABLE Band D4 C4 F1 CH BANK BANK BANK 1 1 2 3 4 1 2 3 4 0 863 125 794 250 794 300 794 350 794 400 636 500 636 600 636 700 636 825 1 863...

Страница 12: ...H x 20 D mm Weight 105g excluding battery 17 CERTIFICATIONS Hereby TOA Electronics Europe GmbH declares that this wireless microphone is in compliance with the essential requirements and other releva...