background image

2

1. IMPORTANT SAFETY INSTRUCTIONS 

• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

• Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

• Only use attachments/accessories specified by the manufacturer.
• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.

INSTRUCTIONS ESSENTIELLES POUR LA SÉCURITÉ

• Lire ces instructions.
• Conserver ces instructions pour référence ultérieure.
• Respecter tous les avertissements.
• Suivre toutes les instructions.
• Ne pas utiliser cet appareil à proximité d'eau.
• Nettoyer uniquement à l'aide d'un chiffon sec.
• Ne pas obstruer les orifices de ventilation. Installer conformément aux instructions du fabricant.
• Ne pas installer à proximité de sources de chaleur telles que des radiateurs, des registres thermiques, des

chaudières ou d'autres appareils (notamment des amplificateurs) produisant de la chaleur.

• Ne pas contourner la fonction de sécurité de la fiche polarisée ou de mise à la terre. Une fiche polarisée est

équipée de deux broches, dont l'une est plus large que l'autre. Une fiche de mise à la terre est équipée de
deux broches et d'une troisième pour la mise à la terre. Cette dernière, la plus large, est prévue à des fins
de sécurité. Si la fiche fournie ne peut être insérée dans la prise électrique souhaitée, consulter un
électricien pour faire remplacer cette dernière.

• Protéger le cordon d'alimentation pour éviter qu'il ne soit piétiné ou pincé, notamment au niveau des fiches,

des prises de courant ou de son point de sortie de l'appareil.

• Utiliser uniquement les accessoires spécifiés par le fabricant.
• Débrancher cet appareil pendant les orages ainsi que lorsqu'il reste inutilisé pendant une période prolongée.
• La maintenance de l'appareil doit être confiée à un technicien après-vente qualifié. Une maintenance s'avère

nécessaire si l'appareil est endommagé (au niveau du cordon d'alimentation ou de la fiche), a été mouillé
par un liquide, un objet est tombé à l'intérieur, s'il a été exposé à la pluie ou l'humidité, s'il ne fonctionne pas
normalement ou s'il est tombé.

Содержание VX-2000DS ER

Страница 1: ...in this manual to ensure long trouble free use of your equipment 1 IMPORTANT SAFETY INSTRUCTIONS 2 2 SAFETY PRECAUTIONS 3 3 NOMENCLATURE AND FUNCTIONS 5 4 BATTERY INSTALLATION 7 5 CONNECTIONS WHEN USING WITH THE VM 3000 SYSTEM 11 6 CONNECTION CABLE LIST 12 7 SWITCHING OFF SYSTEM POWER DC 13 8 BLOCK DIAGRAM 14 9 SPECIFICATIONS 15 TABLE OF CONTENTS ...

Страница 2: ...tructions Conserver ces instructions pour référence ultérieure Respecter tous les avertissements Suivre toutes les instructions Ne pas utiliser cet appareil à proximité d eau Nettoyer uniquement à l aide d un chiffon sec Ne pas obstruer les orifices de ventilation Installer conformément aux instructions du fabricant Ne pas installer à proximité de sources de chaleur telles que des radiateurs des r...

Страница 3: ...be installed near the equipment and the plug shall be easily accessible La prise doit être installée à proximité de l équipement et la fiche doit être facilement accessible External wiring connected to the terminals marked with requires installation by an instructed person When the Unit is in Use Should the following irregularity be found during use immediately switch off the main power or circuit...

Страница 4: ... mm taille de référence The supplied rack mounting screws can be used for the TOA equipment rack only Do not use them for other racks Note correct polarity positive and negative orientation when connecting the power supply cord Reversed polarity connections will cause damage to the system When the Unit is in Use Use the specified power supply unit for the system Note that the use of other power su...

Страница 5: ...40A DC POWER OUT 6 5 4 3 2 1 250V T6 3A L DS SF FUSE LINK SETTING DC AC 6 1 5 4 3 2 6 1 5 4 3 2 DC POWER OUT MAX 25A DC 20V 40V PS IN MAX 25A DC20V 40V DETECT OFF ON ON OFF THERMISTOR PS3 PS2 1 2 PS1 PS IN 5 6 PS3 3 4 PS2 BATTERY POWER IN 24V MAX150A CHARGING OUTPUT 27 3V MAX5A 1 Front Rear Top 2 3 4 5 Rear side Front side 8 9 10 11 12 13 14 15 16 6 120V 60Hz 240W 7 17 1 Power indicator MAIN POWER...

Страница 6: ...compensation for the charging voltage For the installation instructions refer to p 10 8 PS detect switches Always connect a power supply to the terminals 1 2 of the DC INPUT When connecting a power supply to the terminals 3 4 of the DC INPUT set the PS2 switch to ON When connecting a power supply to the terminals 5 6 of the DC INPUT set the PS3 switch to ON 9 AC inlet Using the supplied AC power c...

Страница 7: ...0 mm 5 mm Cross sectional area 16 50 mm2 Usable cable diameter AWG 6 AWG 0 AWG 1 0 Line resistance should be within 4 mΩ in total Cautions on cable connection to the battery terminal Before connecting the battery cable to the battery terminal be sure to fully open the cable clamp by turning the terminal screw counterclockwise Battery terminal Terminal screw Cable clamp Fully open Too narrow to cla...

Страница 8: ...t with the removed screw WARNING Take special care to prevent the battery from being shorted by misconnection of the battery cable If the short occurs the unit may fail Insulating sheet VX 2000DS Attention label Connecting the battery Note correct polarity positive and negative orientation when connecting the power supply cord Reversed polarity connections will cause damage to the system CAUTION N...

Страница 9: ...ble A Cable C Cable B 1 2 VX 2000DS VX 2000DS Battery connection terminals Battery terminals 6 8 Nm 4 1 5 6 Nm M6 8 2 5 6 Nm M8 Use the battery connection cables as short in length and as large in diameter as possible Battery Cable A Cable C Cable B Battery VX 2000DS Battery connnection terminals 250V T6 3A L DS SF FUSE LINK SETTING DC AC 6 1 5 4 3 2 6 1 5 4 3 2 DC POWER OUT MAX 25A DC 20V 40V PS ...

Страница 10: ... Installing a thermistor The thermistor located on the VX 2000DS rear panel is designed to compensate for temperature changes when charging the battery It should be mounted on the side of one battery in between 2 batteries using the supplied thermal insulating sheet to avoid ambient temperature change thereby maintaining the temperature of the thermistor relatively constant Step 1 Clean the exteri...

Страница 11: ...AC 60 Hz 120 V AC 60 Hz 120 V AC 60 Hz 6 3 Cable AWG 10 AWG 8 Cable AWG 10 AWG 8 Cable AWG 6 AWG 0 AWG 1 0 Note Make PS2 and PS3 switch settings according to the total number of connected power supply units VM 3240VA and VM 3240E power supply unit incorporated set PS2 to ON for 2 units and PS2 and PS3 to ON for 3 units Note that these power supply units should be connected to the PS IN terminals 1...

Страница 12: ...NECTION CABLE LIST Round terminal VM 3240VA VM 3240E DC POWER IN 2P screw terminal AWG 10 AWG 8 5 5 8 0 mm2 Connect cables to 2 PS IN terminals Connect 2 cables to PS OUT terminal Below is an example showing that one VX 2000DS is used in a system including 3 VM amplifiers VM 3240VA VM 3240E VM 3240E Lead acid Battery VX 2000DS VM LINK DC POWER DS LINK VM LINK Battery capacity Min 100 Ah Max 100 Ah...

Страница 13: ...tem Step 1 Shift the Setting switch on the VX 2000DS rear panel back to the DC position Step 2 Operate the system normally DS SF FUSE LINK SETTING DC AC 6 1 5 4 3 2 6 1 5 4 3 2 120V DC POWER OUT MAX 25A DC 20V 40V PS IN MAX 25A DC20V 40V 60Hz 240W DS SF DETECT OFF ON ON OFF THERMISTOR PS3 PS2 1 2 PS1 PS IN 5 6 PS3 3 4 PS2 250V T6 3A L BATTERY POWER IN 24V MAX150A CHARGING OUTPUT 27 3V MAX5A SETTIN...

Страница 14: ...DC Output 3 DC Output 4 DC Output 5 DC Output 6 DC POWER OUT DC Input 1 DC Input 2 DC Input 3 DC Input 4 DC Input 5 DC Input 6 DC Input PS IN 150 A max Control Connector DS SF LINK Battery Connection Terminal BATTERY POWER IN Fuse 40 A Fuse 40 A Fuse 40 A Fuse 40 A Fuse 40 A Fuse 40 A Fuse 7 5 A BATTERY CONNECT Indicator BATTERY CHECK Indicator When battery voltage drops below the reference voltag...

Страница 15: ...re and battery failure 1 pair of positive and negative terminals Applicable cable diameter AWG 6 AWG 0 AWG 1 0 Line resistance within 4 mΩ total Cross sectional area 16 50 mm2 0 to 40 C Panel Surface treated steel plate black 30 gloss paint 482 w x 88 4 h x 377 6 d mm 10 5 kg Power Source Power Consumption Applicable Battery Charging Method Charging Current Charging Output Voltage Power Supply Inp...

Страница 16: ...rgy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications Any modifications made to this device that are not approved by TOA Corporation...

Отзывы: