![Toa P-906MK2 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/toa/p-906mk2/p-906mk2_operating-instructions-manual_1122330004.webp)
Rear Panel
P-906MK2, P-912MK2
P-924MK2
AC Power Cord
Connects to power source.
AC Outlet (Unswitched)
Provides AC power for auxiliary equipment with
power consumption of up to 500W.
Impedance Select Switch
Selects the desired impedance.
Enables unbalanced output of low impedance
when this switch is set to "DIRECT".
Output terminals
Connect to speakers.
Module Input Port
Accepts optional PLUG-IN MODULES.
Application determines type of module.
For details, refer to Plug-in Module Instruction
Manual.
Low-Cut Switch
Cut off unnecessary low frequency.
Input Level Switch
Selects input sensitivity. Place in "1V" (0 dBV)
position when normally used as a power
amplifier.
Note: The
position of INPUT-LEVEL SWITCH
should be changed according to modules
used or equipment connected to DIRECT
INPUT TERMINAL.
Direct Input Terminal
Connects directly to external equipment without
using modules.
Unbalanced 10k ohms.
AC Fuse
(250V, 7A)
DC
Fuse
(250V, 8A)
DC
Fuse
(250V, 8A)
Protects amplifier from excessive current drain.
Replace only with same type fuse.
Refer to qualified service personnel if fuse blows
repeatedly.
– 4 –