Toa P-906MK2 Скачать руководство пользователя страница 4

Rear  Panel

P-906MK2, P-912MK2

P-924MK2

AC  Power Cord

Connects to power source.

AC Outlet (Unswitched)

Provides  AC  power for  auxiliary  equipment  with

power consumption of up to 500W.

Impedance Select Switch

Selects the desired impedance.

Enables  unbalanced  output  of  low  impedance

when this switch is set to "DIRECT".

Output terminals

Connect to speakers.

Module Input Port

Accepts optional PLUG-IN MODULES.

Application determines type of module.

For  details,  refer  to  Plug-in  Module  Instruction

Manual.

Low-Cut Switch

Cut off unnecessary low frequency.

Input Level  Switch

Selects  input  sensitivity.  Place  in  "1V"  (0  dBV)

position  when  normally  used  as  a  power

amplifier.

Note: The

  position  of  INPUT-LEVEL  SWITCH

should  be  changed  according  to  modules

used  or  equipment  connected  to  DIRECT

INPUT TERMINAL.

Direct Input Terminal

Connects  directly  to  external  equipment  without

using  modules.

Unbalanced 10k ohms.

AC Fuse

 (250V, 7A)

DC

 

Fuse

        (250V, 8A)

DC

 

Fuse

       (250V, 8A)

Protects  amplifier  from  excessive  current  drain.

Replace only with same type fuse.

Refer to  qualified  service  personnel  if fuse  blows

repeatedly.

– 4 –

Содержание P-906MK2

Страница 1: ...WITH ARROWHEAD WITHIN A TRIANGLE IS INTENDED TO TELL THE USER THAT PARTS INSIDE THE PRODUCT ARE A RISK OF ELECTRIC SHOCK TO PERSONS THE EXCLAMATION POINT WITHIN A TRIANGLE IS INTENDED TO TELL THE USE...

Страница 2: ...e power amplifiers have a low cut switch for a cutoff frequency of 60 Hz and an input level switch for input sensitivity of 1V 0 dBV or 100mV 20 dBV Output terminals provide connections for 4 ohm and...

Страница 3: ...than 30 dB signal level is fed to the inputs by means of the master volume control Normal Indicator LED Yellow LED lights when fed to the proper signal level Peak Indicator LED Red LED lights when amp...

Страница 4: ...etails refer to Plug in Module Instruction Manual Low Cut Switch Cut off unnecessary low frequency Input Level Switch Selects input sensitivity Place in 1V 0 dBV position when normally used as a power...

Страница 5: ...neously Plug the modules into the INPUT PORT sliding it between the guide rails and secure with two screws When INPUT PORT is not occupied cover the PORT with the blank panel and secure it with screws...

Страница 6: ...puts of 8 ohms 25V or 70V BALANCED OUTPUT P 906MK2 P 912MK2 8 ohm 10 4 ohm P 906MK2 5 2 ohm P 912MK2 25V line 83 ohm P 906MK2 41 ohm P 912MK2 70V line Loosen the screw Place the impedance switch in 8...

Страница 7: ...uipment rack use the optional MB 25B MB 35B rack mounting bracket Remove 4 screws securing case MB 25B P 906MK2 P 912MK2 MB 35B P 924MK2 Fix the brackets with attached 4 screws The length of screws sh...

Страница 8: ...nlight with high humidity or dust levels with high ambient temperatures susceptible to vibration with poor ventilation adjacent to heat generating equipment CAUTION Do not remove the case or you may e...

Страница 9: ...Input 100 mV or 1000 mV switchable 10k ohms Main T 8 ohms 25 70 volts balanced Main D 4 ohms unbalanced D Less than 0 5 dB no load to full load T Less than 1 0 dB no load to full load Input level swi...

Страница 10: ...Appearance P 906MK2 P 912MK2 Front View 420 Rear View Top View Side View 320 358 17 10...

Страница 11: ...Appearance P 924MK2 Front View Rear View Top View Side View 420 298 5 334 2 17 11...

Страница 12: ...TOA Corporation KOBE JAPAN PRINTED IN TAIWAN 133 12 116 60...

Отзывы: