4. NOMENCLATURE AND FUNCTIONS 

[Front] 

1. Power switch

Press to turn ON the power. 
Press again to turn the power OFF.

2. Power indicator

Lights green when the power is switched on.

3. Master volume control

Adjusts the output signal level.

4. LED level meter

Indicates an output level.

5. AC inlet

Connects to the supplied power cord.

6. Ground terminal

A functional ground terminal.

7. DC input terminals

Connect to a 24 V DC power supply.

8. Output terminals

Connect to speakers.

9. Remote control terminal block

Permits the unit's power to be remotely turned ON
or OFF by way of make contacts.
For details, refer to p. 6, Emergency Control
Connection and Remote Power ON/OFF Control
Connection.

10. Line output terminals [LINE OUT]

0 dB, 600 

, unbalanced.

Connect to the line input of other equipment.

11. Line input terminals [LINE IN]

0dB or –10 dB, 10 k

, balanced.

Connect to the line output of other equipment.

12. Input level selector switch 

Selects either –10 dB or 0 dB for the Line input
sensitivity level.
When using the unit in conjunction with the
optional A-1800 series PA Amplifier, select 0 dB
for easier adjustment of the sound volume.

5

6

7

8

10

11

9

12

[Rear] 

Содержание P-1812

Страница 1: ...ERATING INSTRUCTIONS PA AMPLIFIER P 1812 Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future referen...

Страница 2: ...eaker Connections 6 5 2 Emergency Control Connection 6 5 3 Remote Power ON OFF Control Connection 6 5 4 Emergency Input and Control Input Terminal Connections 7 6 INSTALLATION 8 7 RACK MOUNTING 8 8 CO...

Страница 3: ...n the power cord as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals neve...

Страница 4: ...ause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Loud noise produced at high volume when power is switched on can impair hearing Do no...

Страница 5: ...9 Remote control terminal block Permits the unit s power to be remotely turned ON or OFF by way of make contacts For details refer to p 6 Emergency Control Connection and Remote Power ON OFF Control...

Страница 6: ...REMOTE IN CONTROL EMER GENCY A 1803 A 1806 A 1812 With the P 1812 s power turned OFF it can be remotely turned ON from the optional A 1803 A 1806 or A 1812 PA Amplifier by making the Remote IN OUT ter...

Страница 7: ...NCY P 1812 Connect this cable when requiring remote power ON OFF control While the Emergency control input terminals remain shorted the power of all the connected A 1800 series and P 1812s is turned o...

Страница 8: ...w to prevent the unit s internal temperature rise 7 RACK MOUNTING To mount the unit in a standard 19 equipment rack use the optional MB 25B Rack Mounting Bracket Attach the MB 25B to the unit using th...

Страница 9: ...ght Note that the sound quality is downgraded when the red indicator remains lit To prevent the accidental change of the setting of Master Volume Control remove its knob after setting it to the desire...

Страница 10: ...jumper to OFF position OFF Factory preset position ON OFF ON Upper view without case Leave the modification described here to a qualified service technician only Please consult your TOA dealer This m...

Страница 11: ...OWER switch 83 100 V 4 16 POWER 220 230 V AC or 240 V AC 50 60 Hz PT Fuse Fuse Fuse Output level meter Relay JP OT C C LINE OUT 0 dB 600 0 dB MASTER volume INPUT LEVEL 0 dB 10 dB REMOTE IN CONTROL EME...

Страница 12: ...dB Master volume max INPUT LEVEL switch 10 dB Control Input POWER REMOTE No voltage make contact input Open voltage 24 V DC Short circuit under 1 mA M3 screw terminal 2 EMERGENCY 3 No voltage make con...

Отзывы: