4.3. Type of Cable
The types of cables are to be determined according to the
following conditions.
Twisted pair wires (such as those used for electronic
push-button telephone) are to be used for wiring between
the Exchange and the stations in principle.
The number of cables pairs laid should be determined
considering the possibility of future expansion of the
system.
Outdoor wires should be used where wiring passes
through inaccessible areas such as ceilings or under floors
where the maintenance is not performed. Indoor wires
may also be used, however, in case where there is no risk
of deterioration due to exposure to heat, etc.
Note
Specifications related to each junction are as follows.
Mini-clamp connector (N-8000EX/8010EX line terminal)
Conductor diameter: ø0.4 – 0.65 mm (AWG22 – 26),
solid wire
Outside diameter:
ø1.05 mm or below
Clip terminal (E-7000TB)
Conductor diameter: ø0.4 – 0.8 mm (AWG20 – 26),
solid wire
Outside diameter:
ø1.5 mm or below
Terminal station (LINE, H, C terminals)
Conductor diameter: ø0.4 – 1.3 mm (AWG16 – 26),
solid wire, stranded wire
4.5. Terminal Station Connection
Step 1. Strip a cable jacket of approx 7 mm to expose
inner cable.
For cables, refer to Type of Cable.
Note
Do not solder plate on exposed inner cables when
using a stranded wire.
Step 2. Loosen the terminal screws and insert the cables.
Step 3. Tighten the terminal screws securely.
Notes
Tug lightly on the cable to be sure that it does not
pull free. If the cable pulls free, loosen the
terminal screw again and reconnect from Step 2.
To avoid stripping the screws, use the
screwdriver appropriate to the screws tightened
into the terminal plug.
4.4. Relations Between Core Diameter of Cable
and Maximum Cable Length
Referring to the following chart as guidelines, design the
distance between the Exchange and stations so that loop
resistance becomes 170 or less.
4.6. Mini-clamp Connector Connection
Connect the mini-clamp connector supplied with the N-
8000EX/8010EX to a cable using a commercially available
tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert
them securely to a cover section (transparent side)
of the mini-clamp connector.
Note
Insert the cable without
stripping the cable jacket.
Step 2. With a pair of pliers, lightly
pinch the mini-clamp cover
and, after ensuring that the
cable is securely inserted,
firmly squeeze on the cover.
Note
Squeeze on the mini-clamp cover until it is
correctly locked.
Step 3. Insert the wired connector (plug) into the
exchange's connector (socket) until it locks into
place.
Cover
(transparent side)
Cable
N-8000EX/8010EX Rear panel
Conductor
Loop
Maximum cable length
diameter resistance
between the Exchange and station.
(mm)
( / km)
(Assuming that the loop resistance is 170
.)
ø0.4
295
570 m
ø0.5
187
900 m
ø0.65
113
1.5 km
ø0.9
58
2.9 km
7 mm
Tighten
Terminal screw
Cable
133-02-002-9700