1-1 

Chapter 1: safety precaution 

Please abide by the warning and the relevant safety tips. 

Please take this manual in convenient place after you reading the guide for future reference. 

 

Warning 

The sign means there is potential safety hazard, when operate wrong may result in death or 

serious injury. 

The sign is used to remind the user that attached is the important operation and maintenance data. 

1

Avoid getting the device wet. 

Do not make the machine wet or expose to rain water or other liquid contamination of the environment, or 

lead to fire or get an electric shock. 

2

Do not use unspecified voltage. 

Using the marked voltage on the machine. 

Using more than the logo of voltage could lead to fire or shock. 

3

Do not scratch the power cord. 

Do not scratch the power cord or cut it. 

Simultaneously, keep the power line far way from heated objects, put heavy things on it will lead to fires or 

electric shock. 

 

Using machine 

1

In case of the anomalies 

Please turn off the power supply immediately when finding the abnormal phenomena, please connect with 

the agency. If you continue to using the equipment, it is likely to catch on fire or resulted in electric shock. 

·The smoke or smell of the machine. 

·The inside of the machine is flooded by water or external intrusion. 

·Machine falling or machine case damage. 

·The power cord damage (wire core is exposed of broken, etc) 

·Malfunction (e.g. no network connection, no sound etc.) 

2

Do not open the machine internal or modify the machine. 

Do not external substance getting into the equipment. 

Please do not put any metallic or inflammable objects into the machine, otherwise it may cause fires or 

electric shock. 

3

Please do not touch it during thundering 

To avoid electric shock, please do not touch the machine and the plug during lightning, etc. 

4

Please do not place containers with liquid or small metal objects on the machine above. 

If containers drop and liquid get into to the machine that will likely catch fires or cause electric shock. 

5

Do not open the machine internal or modify the machine. 

The machine internal contains high voltage parts, once open the cover or modify the machine, it may result 

in fires or cause shock. All the maintenance and other machine modification should be operated by 

professional personnel. 

6

Maintenance and the precautions for not using in a long time. 

While maintenance, if the machine is not been used for 10 days or more, please turn off power supply 

switch for safety. If do not comply with this provision, it will likely cause electric shock or fires. 

Содержание IP-1000AF

Страница 1: ...s Manual IP Audio Interface Unit IP 1000AF Thanks for your purchase of TOA products IP 1000 series Please read the manual carefully to ensure the machine operating in long time and fault free TOA Corporation ...

Страница 2: ...Chapter 1 Safety Precaution ...

Страница 3: ... The smoke or smell of the machine The inside of the machine is flooded by water or external intrusion Machine falling or machine case damage The power cord damage wire core is exposed of broken etc Malfunction e g no network connection no sound etc 2 Do not open the machine internal or modify the machine Do not external substance getting into the equipment Please do not put any metallic or inflam...

Страница 4: ...Chapter 2 Products Description ...

Страница 5: ...rogramming the broadcasting planning the IP audio interface unit can broadcast the server configuration music automatically Broadcasting IP When the IP audio interface unit in the electricity but without cable quickly pressing the reset button will automatically broadcasting IP and subnet mask parameters information System setting via browser User can set network and audio parameters modify login ...

Страница 6: ...keep it in 5s then loosen it Broadcasting IP Electricity status without network quickly pressing and then release it LAN network interface Power interface DC24V 1A Control input output interface IN control input interface E is control input reference place H is control input interface when the two pins is short circuit IP audio interface unit will execute the operation automatically which is setti...

Страница 7: ...Chapter 3 Wiring ...

Страница 8: ...3 1 Chapter 3 wiring 3 1 Wiring Diagram 3 1 Wiring diagram ...

Страница 9: ...single device installation 3 2 1 1 Reference size unit mm 3 2 1 2 Please refer to the following picture for installation Using the countersunk head screw M3 6 to fasten the two wall mounted bracket in the two sides of the device and then installing the device in a suitable position by screw non standard or expansion screw non standard ...

Страница 10: ...t installation bracket suite for optional configuration 3 2 2 1 Reference size unit mm 3 2 2 2 Please refer to the following picture for installation Using the half cabinet mounting bracket MB IP10B BK to fix the two devices as the mentioned method then using length M5 12 and above screw to install the devices in the suitable place Note the screw M5 and nut M5 is not included in the fittings ...

Страница 11: ...ion bracket suite for optional configuration 3 2 3 1Reference size unit mm 3 2 3 2 Please refer to the following picture for installation Using the half cabinet mounting bracket MB IP10B BK to fix the four devices as the mentioned method then using length M5 12 and above screw to install the devices in the suitable place Note the screw M5 and nut M5 is not included in the fittings ...

Страница 12: ...3 5 Chapter 3 Wiring 3 3 Reference size 3 3 Reference size unit mm Note the attached floor mat 10 3 can be pasted on the bottom of the device it is for increasi ng the device antiskid effect on the desk ...

Страница 13: ...Chapter 4 System setting by browser ...

Страница 14: ...address of the IP audio interface unit factory defaults is 192 168 1 101 then press Enter Step 2 Please input the user name and password in the login window of the Web page the defaults is admin Note there is different letter of the use name and password Step 3 It can enter into the Web page after pressed the Enter ...

Страница 15: ...rface unit the defaults is 192 168 1 1 DNS Server 1 The IP of preferred domain interpreter in the interface unit s network DNS Server 2 The IP of standby domain interpreter in the unit s network System server IP address of IP broadcast server System server port The defaults sever number is 2048 please don t modify it if not in specially situation Language The Web page of the speaker s application ...

Страница 16: ... coding PCM means no data be compressed ADPCM means packed data low network data value Line input volume The volume of audio line input 0 15 Broadcasting sampling rate IP audio interface unit sampling rate in broadcasting Broadcast output volume IP audio interface unit output volume in broadcasting 0 15 ...

Страница 17: ...or closed circuit alarm NO control input interface is closed to trigger the alarm OFF control input interface is disconnected to trigger the alarm Alarm input linkage alarm output When the alarm input is triggered configure whether linkage alarm output or not Alarm output linkage recovery time The time of alarm output triggering Note the effective time range is 1 29 S when setting as 0 that means ...

Страница 18: ...4 5 Chapter 4 System setting by browser 4 5 WEB management 4 5 WEB management You can modify the account number and password of the login Web page in the Web management parameters ...

Страница 19: ...4 6 Chapter 4 System setting by browser 4 6 Restarting device 4 6 Restarting device User can click restart device to restart the device ...

Страница 20: ...4 7 Chapter 4 System setting by browser 4 7 Resetting to defaults 4 7 Resetting to defaults Resetting defaults all the parameters will reset to defaults ...

Страница 21: ...4 8 Firmware upgrade Clicking into the firmware upgrade mode to enter the firmware upgrade interface Click browse in the upgrade firmware interface please select the correct upgrade files click on upgrade it will automatically restart after completed the upgrade ...

Страница 22: ...4 9 Chapter 4 System setting by browser 4 9 System log 4 9 System log It can be browsed of the unit log in the Web page click delete all logs can delete all the logs in the Web page ...

Страница 23: ...Chapter 5 Appendix ...

Страница 24: ...ontrol voltage DC30V control electric current 500mA Relay COM contact Control voltage DC30V control electric current 500mA Relay NO contact Control voltage DC30V control electric current 500mA Network I F 10BASE T 100BASE TX automatically determination Network protocol TCP UDP ARP ICMP IGMP Working temperature 0 40 Working humidity Lower than 90 RH No dew point Accessories 5P wiring terminal 1PC 4...

Страница 25: ...TOA Corporation 201611 ...

Отзывы: