background image

Specifications

Type
Control
Calling Type

Speech Method

Dialing Code
Line Capacity

Link Capacity

Number Scheduling

Personal Number

Scheduling
Service Signal Tones

Wiring

Voice Transmission
System

Minimum Input

Signal Level

PAM Time Sharing System

Stored Program Control System
Signal Tone Calling or Voice calling

Hands-free Calling (one calling tone) or
Confidential calling (Continuous calling

tone)

Hands-free conversation and or Handset

conversation
Amplitude Modulated Pulse Number Code
256
(Expandable in 8-line steps)

16 links without Conference
14 links +1 Conference link with
Conference (Expandable in 4-link steps)
No. 200 ~ No. 455 (Standard)

Note: refer to “Function Specifications

for CP-64" for non-standard Number
Scheduling

No. 1000 ~ 1999

8 tones: Calling Tone, Busy Tone, Dial Tone,

Priority Tone, Privacy Tone, Holding

Tone/Confirmation Tone, Zone Paging
Pre-Announcement Tone and All-Call Paging
Pre-Announcement Tone

Non-polar two wire system
Loop Resistance: 300ohms or less
Impedance: 600 ohms, balanced

Cable length: max. 1.0 km (0.4 mm dia)

max. 2.5 km (0.65 mm dia)
max. 3.5 km (0.9 mm dia)

Base Band Signal Transmission (From
Exchange to Station)
Frequency Division Multiplex

Transmission by FM Signal (From Station
to Exchange)

-27 dBm Power Supply Unit: Dark Brown

Refer to “Function Specifications

system composition.

for CP-64" for functions and

Maximum Output Signal
Level + 30 dBm
Input and Output Base Band; 200 Hz ~ 5 kHz
Transmission Band FM Carrier Band; 15 kHz ~ 35 kHz
Noise Level - 40 dBm or less
Crosstalk - 60 dB or less (1.5 kHz)
Speech Gain + 30 dB ±3 dB (1kHz)
Subscriber Insulation
Resistance 3 Megohms or more
Battery for data storage (equipped on CP Unit)
*Type

Ni-Cd Button Battery GB50-3FA1

*Voltage 3.6V
*Capacity 50 mAh
*Period of Battery Charge  approx. 8 days (perfectly discharged)
*Data Holding Period approx. 1 month (25°C/77°F)

approx. 8 days (40°C/104°F)

*Expected Life approx. 5 years (25°C/77°F)
Power Source AC Mains (110, 120, 220, 240V)
(DS-630) ±10% 50/60 Hz

24VDC

Rated Power 410 W (No link occupied)

Consumption 1kW (max.)
Battery for AC power-off operation (Option)
*Type Sealed type Ni-Cd battery NDC-2460

*Voltage 24V
*Capacity 6Ah
*Charge System Trickle Charging, approx. 1/80CA

(20°C/68°F)

*Power-off Operation

Time Approx. 1.5 hrs. (3 X NDC-2460 necessary

per system)

Ambient Temperature

Range 0° ~ 40°C (32° ~ 104°F)
Dimensions 566(W) X 1364(H) X 435(D) mm

(22.28" X 53.70" X 17.12”)

Weight 109 kg (240.30 Ibs.) without battery
C o l o r   Cabinet: Light Beige. Leather Tone

Panel: Metallic Gold

TOA ELECTRIC CO., LTD.

Specifications are subject to change without notice.

Printed in Japan

833-63-102-2A

KOBE JAPAN

Содержание EX-630

Страница 1: ...2 WIRE INTERCOM SYSTEM EXES 6000 System Specifications Exchange EX 630 ...

Страница 2: ...Composition The system is composed of three basic blocks 1 Exchange EX 630 2 Terminal Cabinet and Connecting Cables and 3 Stations 1 EX 630 Exchange a Central Processing Unit CP 64 b Output Control Unit OC 62 c Highway Control Unit HC 64 d Signal Generating Distributing Unit SG 62 e Duplex Link Unit DL 62A f 4 Units without CL 62A unit 3 Units with CL 62A unit Conference Link Unit 1 Conference Lin...

Страница 3: ...gto the number of stations links and optional functions 2 shows either A or B is adaptable 3 shows Toa standard cable 4 shows one pair cable 5 shows two pair cable 6 It is possible to tie line between the EX 630 and the other exchanges EX 610 620 which are employing the CP 63 ...

Страница 4: ... location PI 62 s are also mountable Type 3 in the left position type 4 in the right position 9 Station Paging Assignment Unit SA 64 10 Cabinet Rack CR 271 11 Main Frame FR 630 12 Line Modem Unit LM 62A 13 Jack for Programming Station 15 Data Transmitting Unit DT When this unit is not used mount Perforated Panel PF 012G in this place 16 Power Supply Unit DS 630 17 DC Fuse 20A x 2 129 256 stations ...

Страница 5: ...C 121 Surface Mounted type Back Box for HF 630M S HF 631 M S g YC 150 Flush Mounted type Back Box for HF 640S CU 62 h YC 150E Flush Mounted type Back Box for HF 640S CU 62 i YS 13 Surface Mounted type Back Box for HF 640S CU 62 j PAM 05 Booster Amplifier 5W for HF 650M k DS 100 DC Power Supply Unit for PAM 05 HF 650M CU 62 I YC 024 Surface Mounted Bracket for HF 660M m TK 12 Talk Back Unit n CU 62...

Страница 6: ...ssion by FM Signal From Station to Exchange 27 dBm Power Supply Unit Dark Brown Refer to Function Specifications system composition for CP 64 for functions and Maximum Output Signal Level 30 dBm Input and Output Base Band 200 Hz 5 kHz Transmission Band FM Carrier Band 15 kHz 35 kHz Noise Level 40 dBm or less Crosstalk 60 dB or less 1 5 kHz Speech Gain 30 dB 3 dB 1kHz Subscriber Insulation Resistan...