7.3.1. Camera Address Setting Switch (DIP Switch 1: No. 1 – 8)

Used to set camera address when using the camera in connection with the C-RM500 Remote Controller. Set
the DIP switch so that the address is equal to the connected switcher's channel number. The relationship
between switch settings and camera addresses are shown on page 14. (Factory setting: Only No.1 is “ON”.)

Note

If the address switch number does not match with the connected switcher's channel number or if set to the
same number as that of other camera connected to the same system, the system does not operate correctly.

12

DIP SW1

DIP SW2

DIP SW3

Note

Set the unused DIP switches to the "OFF" position.
If the DIP switches are not set correctly, the camera does not operate correctly.

DIP SW1

DIP SW2

DIP SW3

No.1

No.2

No.3

No.4

No.5

No.6

No.7

No.8

Camera address setting switch 1

Camera address setting switch 2

Camera address setting switch 3

Camera address setting switch 4

Camera address setting switch 5

Camera address setting switch 6

Camera address setting switch 7

Camera address setting switch 8

Communication speed setting 
switch 1

Communication speed setting 
switch 2

OSD switch

Unused

Unused

Unused

Unused

Unused

Unused

Unused

Communication method selector 
switch

Termination switch

Firmware update switch 1 

Firmware update switch 2 

Firmware update switch 3 

Memory clear switch

7.3. Dip Switch Settings

Содержание C-CC714 NT

Страница 1: ...Combination Camera Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment OUTDOOR COMBINATION CAMERA C CC714 NT C CC714 PL C CC764 NT C CC764 PL C C...

Страница 2: ...ing Switch DIP switch 2 No 1 2 13 7 3 3 OSD Switch DIP switch 2 No 3 13 7 3 4 Communication Method Selector Switch DIP switch 2 No 6 13 7 3 5 Termination Switch DIP switch 2 No 8 13 7 3 6 Firmware Upd...

Страница 3: ...et Doing otherwise may result in the unit falling down and causing personal injury and or property damage Only use the unit s dedicated mounting hardware The use of mounting hardware not designated co...

Страница 4: ...servicing to your nearest TOA dealer Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit s cover as this may result in fire or electric shock Do not to...

Страница 5: ...e all these cameras are integrated with a weather resistant outdoor use housing and a built in fan heater they can be freely used outdoors as well 3 FEATURES Digital signal processing realizes high re...

Страница 6: ...ect sunlight could cause the CCD s color filter to deteriorate leading to image discoloration When the C CC774 is recommended that presets be entered into the memory 10 minutes or more after the power...

Страница 7: ...Safety UL Certification does not cover the performance or reliability of the security hardware and security operating software UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGAR...

Страница 8: ...8 1 2 3 4 5 6 Housing Appearance 13 14 15 16 18 19 17 20 19 10 12 9 9 9 9 11 11 7 8 9 9 Housing Bottom Camera Unit Top Camera Unit Bottom 5 NOMENCLATURE Appearance Camera Unit Appearance...

Страница 9: ...6 DIP switch SW1 17 DIP switch SW2 18 DIP switch SW3 19 Camera unit mounting hole 20 Safety wire for camera unit 21 Wall mounting bracket 22 Hook to connect safety wire for housing 23 Suspension brack...

Страница 10: ...tion of the power supply cables video output cables or multicore cables from water System controller Multi switcher Monitor Insulate with vinyl tape 1 2 3 4 5 6 7 8 Power cable Connects to the power s...

Страница 11: ...connectable to a pair of RS 485 lines from termination to termination is 32 units including the Remote Controller The maximum cable length connecting each terminal is 1 2 km in total The camera may n...

Страница 12: ...SW1 DIP SW2 DIP SW3 Note Set the unused DIP switches to the OFF position If the DIP switches are not set correctly the camera does not operate correctly DIP SW1 DIP SW2 DIP SW3 No 1 No 2 No 3 No 4 No...

Страница 13: ...2 No 6 Chooses the RS 485 communication method from Type A used with the C RM500 Remote Controller and Type B Set the switch to the OFF position to choose Type A and to the ON position to choose Type...

Страница 14: ...4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 9 25 41 57 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 10 26 42 58 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6...

Страница 15: ...3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 73 89 105 121 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 74 90 106 122 ON 1 2 3 4 5 6 7 8 ON 1 2 3...

Страница 16: ...3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 137 153 169 185 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 138 154 170 186 ON 1 2 3 4 5 6 7 8 ON...

Страница 17: ...248 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 201 217 233 249 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 202 218 234 250 ON 1 2 3 4...

Страница 18: ...Perform presetting beforehand when controlling the camera using the RS 485 refer to p 11 Camera Settings 8 2 Installation Method The camera can be mounted on a wall a pole or be suspended from a ceili...

Страница 19: ...bracket Use bolts nuts and washers that are appropriate for the wall s structure and composition Be sure to hang the safety wire first when installing the unit 2 Run the cables to be connected to the...

Страница 20: ...top cover then hang the hook to the mounting bracket 3 Run the top cover through the pipe then connect cables Top cover Wall surface Safety wire Housing Insulate the terminals by wrapping the vinyl i...

Страница 21: ...housing against the pipe 4 After confirming the housing direction push the housing up then tighten 2 safety screws Top cover Safety screw Safety screw Housing Align the hole positions Figure viewed f...

Страница 22: ...rk 6 Using the supplied 3 hexagon socket screws attach the top cover 1 to the housing Hexagon socket screw M4 x 8 supplied with Hexagon socket screw M4 x 8 supplied with Aligning the positioning marks...

Страница 23: ...view of the housing Camera unit 1 2 mark Duct Note Insert the camera unit in an oblique direction in the order of 1 to 2 keeping away from the duct of the housing Push the camera unit straight up clo...

Страница 24: ...l it is attached to the housing correctly Mounting it at an angle may cause damage to the camera unit Cross sectional view of the housing Camera unit Mount straight Cross sectional view of the housing...

Страница 25: ...the camera unit to the base unit Camera unit mounting screw Camera unit mounting screw 11 Attach the dome cover Slide down the dome cover s screw head through the housing suspension fitting s slot Ha...

Страница 26: ...Align the dome cover s 4 screws with the hexagon head sleeves inside the housing Note Be sure to attach the dome cover after sliding down its screw head through the housing suspension fitting s slot s...

Страница 27: ...mounting bands into the pole mounting bracket s slots then attach the band to a pole C BC711PM optional YS 60B Mounting Band optional Hexagon head bolt M8 M10 or W 3 8 2 Attach the wall mounting brack...

Страница 28: ...the weight of the units 1 Make a cable entry hole of 50 100 mm on a ceiling Hole diameter 50 100mm C BC711P optional 2 Attach the suspension bracket to a ceiling Note Bolts etc are not supplied with t...

Страница 29: ...or combination camera Dedicated Remote controller Note Combination cameras and outdoor combination cameras can be used in free combinations When a camera fixed installation 1 is used in combinations t...

Страница 30: ...ion 12 x zooming One push stop AF continuous 22 x f 4 0 88 mm 22 times Horizontal 47 3 W 2 2 T Vertical 36 5 W 1 7 T F 1 6 W 3 8 T WIDE end to TELE end Approx 1 3 s preset operation Approx 2 4 s manua...

Страница 31: ...zooming One push stop AF continuous 23 x f 3 6 82 8 mm 23 times Horizontal 54 W 2 5 T Vertical 41 6 W 1 9 T F 1 6 W 3 7 T WIDE end to TELE end Approx 1 5 s preset operation Approx 2 9 s manual operat...

Страница 32: ...e push stop AF continuous 35 x f 3 4 119mm 35x Horizontal 55 8 W 1 7 T Vertical 43 3 W 1 3 T F 1 4 W 4 2 T WIDE end to TELE end Approx 2 s preset operation Approx 3 2 s manual operation Panning Endles...

Страница 33: ...e push stop AF continuous 35 x f 3 4 119mm 35x Horizontal 55 8 W 1 7 T Vertical 43 3 W 1 3 T F 1 4 W 4 2 T WIDE end to TELE end Approx 2 s preset operation Approx 3 2 s manual operation Panning Endles...

Страница 34: ...ONTROLLER Software installation manual 1 Hexagon socket screw M4 x 8 3 Optional Products Wall Mounting Bracket C BC711W Suspension Bracket C BC711P Pole Mounting Bracket C BC711PM Mounting Band YS 60B...

Страница 35: ...35...

Страница 36: ...133 05 406 0A...

Отзывы: