Toa BG-220 Скачать руководство пользователя страница 10

10

7. MUTING FUNCTION

7.1. Manual Mute

Step 1.

Place the Line 2 and/or Line 3 input in Mute Receive (muted) mode using the Function switch No. 5
for Line 2 and No. 6 for Line 3.

Step 2.

Close the Manual mute (+) and (–) terminals.
The Input set for Mute Receive in 

Step 1

is muted.

Step 3.

Open these terminals. 
The signal being muted returns gradually to its original level in about 1 to 5 seconds.

Note: 

This function is active regardless of the Automatic mute ON/OFF setting using the Function switch.

Manual mute and Automatic mute are available for the muting function.
Manual mute is a function to mute the LINE 2 and/or LINE 3 input when the manual mute terminals are
closed.
Automatic mute is an audio-signal activated mute function to automatically mute the LINE 2 and/or LINE 3
input when audio signals enter the MIC/LINE 1 input.
Neither Manual mute nor Automatic mute works on the MOH output.

UNIT

BREAKER

2A

PUSH

RESET

MOH OUT (ZONE2)

SPEAKER OUT (ZONE1)

600Ω

18Ω 140Ω

COM

CLASS 2 WIRING

DO NOT USE THESE 4Ω , 25V AND 70V
TERMINALS AT THE SAME TIME.

70V

25V

H

C

E

LEVEL

MOH ASSIGN
1. MIC/LINE 1
2. LINE 2
3. LINE 3

7. AUTO MUTE (MIC/LINE 1)
8. MIC (ON)/LINE (OFF)

4. - - - - -
5. LINE 2
6. LINE 3

MUTE SENSE

MUTE RECEIVE

MANUAL

MUTE

MIC / LINE 1

LINE 3

H

E

LINE OUT

600Ω

H

E

LINE 2

H

E

H

C

+

10

0

10

OFF

ON

0

-

E

Manual mute terminal

Mute sensitivity control 

Function switch Nos. 5, 6, and 7

MOH ASSIGN

1. MIC/LINE 1
2. LINE 2
3. LINE 3

7. AUTO MUTE (MIC/LINE 1)
8. MIC (ON)/LINE (OFF)

4. - - - - -
5. LINE 2
6. LINE 3

MUTE SENSE

MUTE RECEIVE

MANUAL

MUTE

MIC / LINE 1

H

C

+

10

0

OFF

ON

-

E

7.2. Automatic Mute

Step 1.

Set the Function switch No. 7 to ON.
The MIC/LINE 1 input is placed in Mute Send mode (audio signal-activated muting mode).

Step 2.

Place the Line 2 and/or Line 3 input in Mute Receive (muted) mode using the Function switch No. 5
for Line 2 and No. 6 for Line 3.

Step 3.

Set the muting level using the Mute sensitivity control.
Adjusts the threshold level for the MIC/LINE 1 input to activate the muting function. Turn clockwise to
increase the threshold level (lower sensitivity), and counterclockwise to decrease it (higher
sensitivity).

Note

The audio signal level to activate muting is independent of input volume settings. So, the Mute
Receive input is muted if a signal enters the MIC/LINE 1 input even when the input volume is turned
down. To avoid unwanted muting caused by unintentional inputs such as background noise and noise
sound, it is recommended to cut the audio signal at the input equipment (such as a microphone with
talk switch).

Step 4.

The Input set for Mute Receive in 

Step 2

is muted by the MIC/LINE 1 input audio signals.

Step 5.

When the input signals are not present, the signal being muted returns gradually to its original level in

about 1 to 5 seconds.

Содержание BG-220

Страница 1: ...tomatic Mute 10 8 MOH OUTPUT ASSIGNMENT 11 9 2 CHANNEL BROADCAST 11 10 OPERATION 12 11 INSTALLATION PRECAUTIONS 12 12 RACK MOUNTING BRACKET ATTACHMENT 12 13 VOLUME SETTING 13 14 VOLUME CONTROL COVER 1...

Страница 2: ...to your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where th...

Страница 3: ...is may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the unit falls or the unit case breaks If the powe...

Страница 4: ...e rack Keep the amplifier over 10 cm 3 94 away from objects that may obstruct air flow to prevent the unit s internal temperature rise When the Unit is in Use Do not place heavy objects on the unit as...

Страница 5: ...3 input mixer amplifiers for background music and general announcement Power output is rated at 20 W for the BG 220 and 35 W for the BG 235 These units are suited for use in bars retail stores and ban...

Страница 6: ...11 Note Bass and treble controls are not active for this output 12 MOH volume control Adjusts the MOH output signal level 11 4 Line 2 input volume control Adjusts gain of the Line 2 input Turn the kn...

Страница 7: ...ecommended to cut the audio signal at the input equipment such as a microphone with talk switch 15 Manual mute terminal Closing between and terminals mutes the input signal set for Mute Receive by the...

Страница 8: ...12 24 Cable end treatment 7 mm 7 mm 20 mm 2 core shielded cable Solid cable and stranded cable Wiring Procedure Step 1 Wiring the supplied removable terminal plug 1 1 Loosen the terminal screws to ins...

Страница 9: ...in the figures below represent total speaker load impedance 70 V LINE Total impedance 245 BG 220 140 BG 235 25 V LINE Total impedance 31 BG 220 18 BG 235 Speaker output terminal COM 4 Speaker output t...

Страница 10: ...0 0 10 OFF ON 0 E Manual mute terminal Mute sensitivity control Function switch Nos 5 6 and 7 MOH ASSIGN 1 MIC LINE 1 2 LINE 2 3 LINE 3 7 AUTO MUTE MIC LINE 1 8 MIC ON LINE OFF 4 5 LINE 2 6 LINE 3 MUT...

Страница 11: ...ch No 1 MIC LINE 1 input Function switch No 2 LINE 2 input Function switch No 3 LINE 3 input 9 2 CHANNEL BROADCAST Input signals set in Section 8 are output to the MOH output 2 channel broadcast can b...

Страница 12: ...the screws that are appropriate for the rack When mounting the unit in an equipment rack the inside of the rack must be sufficiently ventilated To achieve sufficient ventilation also mount the option...

Страница 13: ...e control so that the signal indicator lights intermittently Note that the sound quality is downgraded when the peak indicator remains lit Mounting bracket Joint bracket Machine screw M4 x 10 Amplifie...

Страница 14: ...AMP MIX AMP 25 V LINE 4 COM H C E OT MOH OUT ZONE 2 600 1 MOH ASSIGN MIC LINE 1 2 MOH ASSIGN LINE 2 3 MOH ASSIGN LINE 3 4 5 MUTE RECIEVE LINE 2 6 MUTE RECIEVE LINE 3 7 AUTO MUTE MIC LINE 1 8 MIC ON LI...

Страница 15: ...15 16 DIMENSIONAL DIAGRAM Unit mm in 1800 70 87 210 8 27 6 M4 265 10 43 249 9 8 40 1 57 165 6 5 15 0 59 58 4 2 3 94 3 3 71 88 4 3 48...

Страница 16: ...Output Regulation 1 kHz Under 2 dB no load to full load S N Ratio Microphone Line 1 Over 60 dB Line 2 Over 80 dB Line 3 Over 80 dB Band Pass 20 Hz 20 kHz Tone Controls Centered Tone Control Bass 10 d...

Отзывы: