Indicates a potentially hazardous situation which could result in
moderate or minor personal injury, and/or property damage if ignored
or mishandled.

CAUTION

When Installing the Alarm Input Unit
• Never insert nor remove the power supply plug with wet hands, as an electric shock may result.
• When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord

itself. The power supply cord may be damaged, possibly causing a fire or electric shock. 

• Do not block the ventilation slots in the unit's cover. Doing otherwise may cause heat to build up inside the

unit, possibly causing a fire. 

• Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the

heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric
shock. 

• When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the

power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. 

• When mounting the C-AL80 Alarm Input Unit in an equipment rack, ensure that the temperature inside the

rack is lower than its maximum ambient temperature.

When Using the Alarm Input Unit
• Do not place heavy objects on the unit. Such objects may fall or the unit may tip over, possibly resulting in

personal injury. 

• Clean the inside of the unit periodically, and contact your TOA dealer regarding the cleaning. If dust is

allowed to accumulate in the unit over a long period of time, a fire may result. 

• If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean them

periodically. Also, insert the plug in the wall outlet securely. 

• Switch off the power and unplug the power supply plug from the AC outlet for safety purposes when cleaning

or leaving the unit unused for a long period of time. A fire or electric shock may result. 

2. GENERAL DESCRIPTION

Using no-voltage contact inputs, TOA's C-AL80 Alarm Input Unit activates the remote controller's alarm
facilities or remotely controls the remote controller. The C-AL80 has a total of 32 alarm or remote inputs. By
making master-sub connections, up to 8 C-AL80 units can be connected to each other, creating a total of 256
alarm/ remote inputs.

3. HANDLING PRECAUTIONS

• Use the C-AL80 Unit in locations where the temperature fluctuates in the range of 0 – 40°C, and humidity is

under 90% (no condensation must be formed).

• When permanently installing the Unit, avoid blocking ventilation slots in the Unit's cover and bottom panel,

and keep the Unit's front, rear, and sides at least 10 cm from the wall. Doing otherwise may cause heat to
build up inside the Unit and result in the Unit's failure.

Note
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.

Modifications
Any modifications made to this device that are not approved by TOA Corporation may void the authority
granted to the user by the FCC to operate this equipment.

L version complies with Part 15 of the FCC Rules.

Содержание ALARM INPUT UNIT C-AL80(H)

Страница 1: ...structions in this manual in order to ensure long trouble free use of your Alarm Input Unit Note The C AL80 Alarm Input Unit is designed to be used in conjunction with TOA s C RM500 Remote Controller to enable their alarm operations or remote control Thus the C AL80 Alarm Input Unit can only be used while connected to a C RM500 Remote Controller ...

Страница 2: ...tings 8 5 4 Alarm Interval Settings 8 6 USING THE ALARM REMOTE FUNCTION 6 1 Alarm Remote Input 9 6 2 Alarm Remote Output 9 7 CONNECTION EXAMPLES 7 1 Example of the Combination with the C SC80 Remote Controller 10 7 2 Example of the Combination with the C SC50A Remote Controller 11 8 MASTER SLAVE CONNECTIONS 8 1 Unit Number Settings 12 8 2 Master Slave Terminal Connections 12 9 RACK MOUNTING 14 10 ...

Страница 3: ...ersonal injury Do not install the unit in close proximity to medical equipment since the electromagnetic wave from the unit may adversely affect the medical equipment When Using the Alarm Input Unit Do not place cups bowls or other containers of liquids or metal objects on top of the unit If they accidentally spill into the unit this may cause a fire or electric shock Do not insert foreign objects...

Страница 4: ...tlet securely Switch off the power and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for a long period of time A fire or electric shock may result 2 GENERAL DESCRIPTION Using no voltage contact inputs TOA s C AL80 Alarm Input Unit activates the remote controller s alarm facilities or remotely controls the remote controller The C AL80 h...

Страница 5: ...connections cascade connections for multiple C AL80 units Up to 8 units can be connected for the Master Slave relations Refer to p 19 Master Slave Connections 4 Mode Selection Switch Alarm Remote Abbreviation No 1 Abbreviation No 9001 Remote ON Remote OFF Edge Level From left to right 1 Switches the rear panel mounted terminal block input between Alarm and Remote mode 2 It cannot be used 3 It cann...

Страница 6: ...a connected to the Remote Controller Refer to p 11 Using the Alarm Remote Function 7 Master Slave Terminal Master Slave Non LPS These input and output terminals are used to make master slave connections for multiple C AL80 Units The master slave connection is possible for up to 8 C AL80 units Both left and right terminals provide the same function 8 Camera Selection Output Terminal Camera Selectio...

Страница 7: ...he switch to the lower Alarm position when selecting Alarm and to the upper Remote position when selecting Remote The Alarm position permits alarm indication to be displayed and a buzzer to be sounded when there is an alarm signal input However when a master slave connection is established only the master unit s setting is valid Factory preset position Alarm 5 2 Abbreviation Number Settings Please...

Страница 8: ...for a specified period of time Alarm Interval set by the Remote Controller when an alarm signal is received If Level is selected the system continues to operate on alarm as long as an alarm signal is input In this event the alarm cannot be reset with the Alarm Reset key of the Remote Controller Set Mode switch 4 to the lower Edge position to select Edge and upper Level position to select Level Whe...

Страница 9: ...r input with the Mode Selection switch Refer to p 7 Alarm input Enables spot alarm operations using such external equipment as sensors Remote input Selects the channel and position of the camera corresponding to the abbreviation number when shorted to GND Only the channel is selected for other cameras than the Combination Camera Electrical Alarm Remote Input Specifications Input 32 channels no vol...

Страница 10: ... Dedicated remote control terminal Fixed cameras Input Input Video input output A B A B Combination camera 1 2 3 4 5 1 2 3 4 5 Camera control cable Alarm input cable GND GND Alarm input terminal RS 232C The use of each camera s alarm input permits up to 8 sensors to be connected for each camera RS 232C reverse cable D sub 9 pins female to D sub 9 pins female Camera control terminal Switcher contro...

Страница 11: ...ON 1 2 3 4 Unit No OFF ON OFF RS 485 Termination switch 11 ON Termination OFF RS 485 Termination switch 11 ON Termination OFF RS 485 Termination switch 11 ON Termination OFF RS 485 Termination switch 11 ON Termination To Slave Unit 3 From Slave Unit 6 7 2 Master Slave Connection Example For details about unit number settings etc refer to p 19 Master Slave Connections Note Set the RS 485 Terminatio...

Страница 12: ...not operate correctly if the change is made with the Power switch set to ON Settings Use Unit No Setting switches 1 3 to perform settings Refer to the following table for switch settings of the master unit and slave units Assign slave unit numbers in consecutive order with the lowest number first Be sure that no numbers are duplicated 8 2 Master Slave Terminal Connections Connect the Master Slave ...

Страница 13: ...able with plug for connection between the Master Slave terminals Refer to the figure shown below and note the correct polarity when making the connection Pin No 1 Pin No 1 Control signal positive Pin No 3 Pin No 3 Control signal negative Do not connect pins Nos 2 4 and 5 Note Incorrect wiring may result in the unit s failure The maximum cable length is 1 2km ...

Страница 14: ...ck remove 4 plastic feet on the bottom plate and attach an optional MB 23B mounting bracket Note Use the Alarm Input Unit in locations with ambient temperature of between 0 C and 40 C Be sure to mount the Alarm Input Unit below the heat generating components and mount the perforated panel between the Alarm Input Unit and such a heat generating component as required Avoid installing the Alarm Input...

Страница 15: ...L80 Unit s is not correctly connected to the Remote Controller The C AL80 Unit s Mode Selection switch is not set to Remote Abbreviation number corresponding to the Remote Controller is not registered If a master slave connection has bee established the Unit Number Setting switch Mode Selection switch or RS 485 Termination switch is not correctly set Cables are not correctly connected the C AL80 U...

Страница 16: ...rm Remote 1 bits DIP switch Alarm Remote selection Alarm time 1 bit DIP switch Edge Level selection RS 485 terminal Rear mounted slide switch RS 485 termination Enable Disable selection indoor use 0 C to 40 C Panel Alminum extrusion black 30 gloss Case Pre coated steel plate black 30 gloss 420 W x 96 6 H x 335 8 D mm 3 6 kg Power Source Power Consumption Alarm Remote Input Control Input Output Mas...

Отзывы: