Страница 2: ...ications 4 4 Description of Panels and Symbols 6 5 Installation 7 6 General Function 10 7 Test Mode 11 8 Setting Mode 13 9 Calibration 18 10 Infrared Remote Controller 19 11 Wireless Specifications 20 12 RS232C Format 21 13 Real Time Clock 22 14 Check Message 23 ...

Страница 3: ...tact our customer service team or system installation staff in advance and any modification should be conducted under our surveillance Do not connect incompatible adaptor Use only adaptor approved by TMT for use with this particular model The use of any other types may invalidate any approval or warranty and may be dangerous For availability of approved enhancements please check with your dealer D...

Страница 4: ...p to 8 load cell Input sensitivity 0 2uV D Input signal range 0 39mV Non linearity 0 0015 of FSR max External resolution Up to 100 000 counts Output data rate 4 7 to 200 measurements per second Temperature range 20 60 Product weight TI 2300 1 2kg TI 3000 2 2kg Power 12V 1A Parts Power adaptor IR remote controller OP 01 RS232C RTC Real time clock 2solid state relays and 4inputs OP 02 Use the vehicl...

Страница 5: ...5 Dimensions 1 TI 2300 2 TI 3000 ...

Страница 6: ...to be in stable condition ZERO Indicates that scale is stable and at zero TARE Indicates that scale is currently using a tare HOLD Indicates that the HOLD feature has been activated Keys Power Use to turn on off Zero Return the display to 0 Tare Use to weigh with tare weight Hold Use to weigh unstable things ...

Страница 7: ...7 5 Installation 12V Power adaptor RED GND Power adaptor BLACK TX3 Extra RS232C TXD RX3 Extra RS232C RXD GND Extra RS232C GND ...

Страница 8: ...ot used GND TX2 RS232C TXD OP 01 RX2 RS232C RXD OP 01 GND RS232C GND OP 01 EX EX SIG SIG GND POWER External key 4 contact 4inputs OP 01 ZERO TARE HOLD GND EVCC 2 solid state relays contact OP 01 OUT1 EVCC OUT2 ...

Страница 9: ...ed with the touch keys 2 Solid state relay circuit EVCC range DC12 28V R load range 2KΩ Output conditions Output Conditions OUT2 ON low limit Low limit Measured value High limit OUT1 ON high limit High limit Measured value OUT1 2 OFF Measured value Low limit ...

Страница 10: ...eighs moving things Press HOLD KEY when the scale is empty Initial Zero State The weight display will indicate AH ON HOLD LAMP is on After loading a thing if the weight turns stable then a display shows and average weight will appear The weight of a loaded thing is displayed To escape the automatic hold mode when zero point is on press HOLD KEY Then the message of AHOFF is displayed and HOLD LAMP ...

Страница 11: ...own If press a TARE KEY move on TEST 2 TARE HOLD SUM TEST 2 Display Test Display Description TEST 2 runs off automatically and a display is on If press the TARE KEY move on TEST 3 TEST 3 Load Cell Test Display Description 2072 The value is the conversion constant for A D converter The value may be different according to scale s condition Check whether digital value is changing If the digital value...

Страница 12: ... TEST 4 Solid state relay output test Display Description OUT 0 ZERO KEY All outputs are turned off HOLD KEY Increase the output number this output is turned on If press the TARE KEY move on weighing mode ...

Страница 13: ... move on next menu 3 Menus F01 Assignment of weight variation rate 1 9 Settings Meaning F01 1 Indicating rate of weight is fast F01 5 Indicating rate of weight is moderate F01 9 Indicating rate of weight is very slow F02 Weight backup 0 1 Settings Meaning F02 0 Not used F02 1 Used F03 Assignment of Stabilization speed 1 9 Value Description F03 1 Recognized as stable for change under half graduatio...

Страница 14: ...nge under 4 5 gradation for 9 sec F05 Assignment of Hold speed 1 9 Settings Meaning F05 1 Very fast F05 5 Normal F05 9 Very slow F06 Auto hold function 0 1 Settings Meaning F06 0 Manual F06 1 Automatic F07 Initialization of hold value 1 9 Settings Meaning F07 1 In the zero weight F07 5 In the 5 division weight F07 9 In the 9 division weight F08 PC Printer connection 0 2 Settings Meaning F08 0 Wire...

Страница 15: ...d key F10 1 key Remote controller F11 Item number Identification number of each Item 0 9 Settings Meaning F11 0 Item No 0 0x01 F11 5 Item No 5 0x05 F11 9 Item No 9 0x09 F12 Print line feed 0 9 Settings Meaning F12 0 1 line feed F12 5 6 line feed F12 9 10 line feed F13 Print form 0 2 Settings Meaning F13 0 Form 0 weigh No Item No weight F13 1 Form 1 Serial No Item No weight When the F09 1 is select...

Страница 16: ... Not used F15 1 Send data command key Print format F15 2 Send data command key 18bytes format F16 Auto transmit at data hold 0 1 Settings Meaning F16 0 Not used F16 1 Used The hold data will be sent by according to set in F08 F17 Stream mode 0 2 Settings Meaning F17 0 Not used F17 1 Stream mode for RS232C F17 2 Stream mode for TF200 2013 10 13 12 00 001 ID_9 25 kg 2013 10 13 12 00 SN_02 ID_9 25 kg...

Страница 17: ...git place to be inputted with ZERO KEY Input a figure with HOLD KEY Press TARE KEY to enter the value F19 Setting high limit not included weighing points Settings Meaning 500 50 0kg In case of one decimal point Select a digit place to be inputted with ZERO KEY Input a figure with HOLD KEY Press TARE KEY to enter the value ...

Страница 18: ...ut value increment of digit shift next menu 3 Minimum division increase decrease shift next menu 4 Balance weight increment of input value increment of digit shift next menu It is recommendable to calibrate using a balance weight which weights 50 of the maximum capacity or more in terms of linearity 5 Zero calibration Check unload the tray and press key 6 Span calibration Load the weight which was...

Страница 19: ... TI series KEY CLEAR Refer to F09 SUM KEY Use to add weights If press a SUM KEY the sum of weights is displayed After that about 2 sec later a weighing mode is reverted Weight of less than 5 digits is not summed Maximum of sum weights is 99999 and if it exceeds the weights is initialized to 0 2 Specification List Description Available Distance 6 m 10 m Available Angle 60 Power 3V 1 5V AA 2pcs ...

Страница 20: ...put power Max 4dBm Channel width 2 MHz Frequency offset 30ppm Transmit data rate 250Kbps 500Kbps Receiver sensitivity 99dBm PER 1 Maximum input level 0dBm RF In out impedance 50 ohm TXRF RXRF Spurious 2nd harmonics 30dBm Radio link effective range Approx 100M Open space ...

Страница 21: ... None Code ASCII 3 Format 18byte Start Code Blank Lamp Status Weighing data Unit Stop code S U T S 7byte k g CR LF Start code ST Stable US Unstable Lamp status byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 One Decimal Place Two Decimal Place Three Decimal Place Stable Zero Tare Hold Weighing data 8byte 13 5 kg 1 3 5 135 kg 1 3 5 CR 0x0D LF 0x0A ...

Страница 22: ... the TARE KEY again 2 Keyboard Used to increase the setting constant one by one Used to move the input value to the left or right by one place Used to save the value and to move next menu 3 Menu No Display Description 1 YEAR 2013 Modify the year 2 DATE 10 13 Modify the date 3 TIME 18 00 Modify the time 4 END The end ...

Страница 23: ...g of current resolution is not possible due to the error in load cell Proceed calibration again with less resolution The weight for span calibration is set to be exceeded 10 100 of the maximum capacity of the scale Set the weight for span calibration in CAL3 to be within the 10 100 of the maximum capacity When a thing is over weighed within the maximum weight value the error message is displayed D...