![TMS Lite LC-18-SQ-4CH Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/tms-lite/lc-18-sq-4ch/lc-18-sq-4ch_user-manual_1121991009.webp)
TMS Lite
LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
8
Trigger Mode
Trigger mode provides most flexibility for variable timing light output. The light output ON
when input trigger signal received and OFF when no input signal.
Current Multiplier
Current Multiplier setting provides more precise control of lighting intensity for lightings with
different current ratings.
Current Multiplier setting range = 1-10
1 = 10% of max output current (100mA)
2 = 20% of max output current (200mA)
3 = 30% of max output current (300mA)
4 = 40% of max output current (400mA)
5 = 50% of max output current (500mA)
6 = 60% of max output current (600mA)
7 = 70% of max output current (700mA)
8 = 80% of max output current (800mA)
9 = 90% of max output current (900mA)
10 = 100% of max output current (1000mA/1A)
For example: if the lighting’s current rating is 260mA, current multiplier can be set to 3, setting
the maximum output current to 300mA. So the lighting’s intensity can be adjusted from low to
high within the range of 0-255.
If multiplier is set too high, for example 10 (100% of max output = 1A), the adjustable intensity
range for the lighting is only about 0-67. Setting the intensity value to 68 or higher will not
have any effect towards the lighting output brightness.
External Trigger
Lighting Strobe