TMS Lite
ANALOG LIGHTING CONTROLLER UNIT
-
4
-
ANGX-1000-CH1 SPECIFICATIONS
CONTROL:
VR Knob
Manual Control (Adjustable)
General:
Dimension
L:330 mm W:123 mm H:93mm
Power Input
100V - 240V AC 50/60 Hz (240W)
Board Max Power Consumption 5.5A @ 26.5V
Board Voltage
26.5VDC
Channels:
1 Channel
Output Mode
Constant
Output Current
Selectable maximum current 3A or 5A
From 130mA up to 5A
Lighting Output
Voltage
24V Max.
Functions:
Constant
Lighting Intensity
VR Adjustable
Intensity Range
0 ~ 10 steps
Note:
The intensity of light is affected by the length of the lighting cable.
Configuration
Connections:
For ANGX-1000-CH1-24V to operate properly, the unit terminals must be connected
correctly. The terminals voltage polarity must be followed accordingly to prevent
damage to the unit.
−
Supply Voltage Selection
The unit can operate on 100V AC - 240V AC.
−
Power Input Terminals
Connect the Power Cord Cable to 3-pin chassis plug of controller.
Connect a power cord cable to 100V - 240V AC supply line to the controller
chassis plug for supply AC voltage to controller.
−
Lightings Output Terminals Channel (CH1)
The lighting connector is to be connected to 24V-Lighting
Precautions
−
Do not open the cover of the product
Electric shock may occur, do not touch the internal parts.
−
Install the unit at a site with good ventilation
Poor ventilation result over heating and cause the unit to fail.
−
Do not use the unit in a closed system, as it becomes hot
Cool down with fans, if it is used in a close space.
−
Do not rest your hand or any part of your body on the product casing
Warning: The casing of the product is hot. Its temperature may raise to 80 °C.