background image

39

7.6. 

Typical malfunctions and troubleshooting

7.7. 

Safety measures for stove exploitation

Prior to the start of the heating season, the stove, gas burner and 

chimney must be inspected and, in case of faults, repaired. Gas sauna 
stove is not allowed to be used in case it has any malfunctions. See p. 

7

.1 

for signs of properly working stove.

Caution! It is forbidden to leave a heating up stove unattended, and 

entrust supervision of it to young children and persons 
under the influence of alcohol, drugs, medicines, etc.

Caution! Do not touch the heated surfaces of the stove with bare hands 

or other exposed parts of the body to avoid burns and 
injuries.

Caution! Do not place flammable substances and materials closer than 

Trouble type

Disturbance of a 

burning process
Emergence of 

fuming
Emergence of 

smell

Drops on an 

external surface of  

a tube
Slow heating of a 

premise

Burnout of the fire 

bar and (or) side 

walls

Possible cause

Chimney draft has 

deteriorated
Chimney draft has 

deteriorated
Evaporation of remains 

of oils and volatile 

components of enamel

Insufficient 

impermeability of joints 

of chimney
Insufficient heat 

insulation of a premise 
Incorrectly selected stove

Have used a fuel with 

high burning 

temperature 
Overheating of the stove

Troubleshooting

Clean the chimney 

Clean the chimney 

Preheat the stove in 

accordance with point 

8.2

. in a place of 

installation with 

maximum ventilation of 

a premise
Densify joints with heat-

proof sealant

Make warmer a premise

Select a stove of higher 

power
Repair or replace the 

stove, thereafter, use 

recommended fuel

Содержание Valerian

Страница 1: ...Valerian Wood Burning Heating Stove Made in Russia Operating manual...

Страница 2: ...art or whole is prohibited without prior written permission from the manufacturer The manufacturer reserves the right to make changes in the design of the fireplace that do not impair the fireplace s...

Страница 3: ...original design with a translucent screen n Valve for burning intensity adjustment 3 Product Range The batch production includes Valerian stove models with the power capacity of 8 15 20 kW 4 Specific...

Страница 4: ...800 mm 655 750 750 D mm 460 540 540 Weight kg 54 5 71 87 4 Size of the fire door mm 295 295 295 Firing chamber volume L 35 52 65 Maximum load of firewood L 26 46 59 Maximum length of a wood piece mm...

Страница 5: ...alve 4 located at the door For fire safety the valve is covered with the deflector 5 from the furnace side By regulating the valve 4 you can force the burning and obtain a strong high temperature flam...

Страница 6: ...hazards Caution Do not use alcohol and flammable compounds to light up the stove Caution It is not allowed to burn glossy paper chipboard laminate and hardboard trimming as this can generate gases th...

Страница 7: ...ove 1 Convection pipes 2 Door of the furnace chamber 3 Translucent screen 4 Air control valve 5 Deflector 6 Deflector 7 Firebox 8 Convector panels Pictures of the product shown in this Operating Manua...

Страница 8: ...ire perimeter n The glass of the door is free of cracks chipping and other damages n Air control valve flap moves freely and tightly seals the channel when closed 7 2 Preparing the room for the stove...

Страница 9: ...fter it is completely cooled down Caution The stove is heavy Make sure that you have the skills and equipment to move it Caution It is forbidden to install the stove in places where it will create an...

Страница 10: ...normal process of combustion This stove is designed only for work on natural draft The stove should have its own chimney Caution It is forbidden to connect the stove to any ducts except when the duct...

Страница 11: ...oof roofing 5 Ceiling divider 6 Start sandwich 7 Wall made of a combustible material 8 Stove base made of a non combustible material 9 Metal sheet applied to asbestos paper to protect wall made of com...

Страница 12: ...lements of the building In the case of installing a thick walled metal ceramic or other chimney of large mass it is necessary to unload the stove from its weight Caution The manufacturer is not respon...

Страница 13: ...y call the firemen 7 5 Using the stove Caution Before lighting up the stove please make sure that there is a draft in the chimney in order to do so just take a lit match to the open door of the stove...

Страница 14: ...e recently lit stove operating in set temperature a slight output of smoke in the room is possible to appear Further intake regulation which affects combustion intensity is done by opening and closing...

Страница 15: ...bstances and materials closer than Trouble type Disturbance of a burning process Emergence of fuming Emergence of smell Drops on an external surface of a tube Slow heating of a premise Burnout of the...

Страница 16: ...ove is installed Sensors should be installed at a distance from the stove preventing false triggering When installing operating and maintaining gas sensors follow the manufacturer s instructions In ca...

Страница 17: ...t n Once every three months for heating stoves n Once every two months for stoves and fireplaces of continuous action n Once a month for kitchen stoves and other stoves of a contin uous long term load...

Страница 18: ...r and can t damage the glass while closing the door Do not make a fire near the glass or in a place where it may be near the glass during the burning process Do not use materials which can scratch or...

Страница 19: ...warehouses of the Supplier and the Customer The period of storage in the retail package without re conservation should not exceed 12 months If the fireplace is stored at high humidity its painted surf...

Страница 20: ...h a specific note in Acceptance Certificate and Warranty section of this Manual Warranty liabilities do not cover parts that are subject to normal wear protection screens protection flue liners clay f...

Страница 21: ...are terminated earlier and not subject to renewal in the future Establishment of facts of non compliance of the Consumer with the Product s installation and or operation technical requirements breach...

Страница 22: ...46...

Страница 23: ...hnical standards meets Technical Specifications 4858 001 0136596940 2011 and is accepted as ready for operation _______________ _______________________ ____ ______________ 20 ___ PURCHASE CERTIFICATE...

Страница 24: ...Consumer Information Centre LLC TMF Legal address 99 Vatutina Str 630024 Novosibirsk Russia Wholesale Department 7 383 353 71 39 Retail Department 7 383 230 00 85...

Отзывы: