TMC V2Skim Series Скачать руководство пользователя страница 7

TROUBLE SHOOTING

Problem:The skimmer is not working properly

1. Possible Cause:Water level is too low.

Solution:Alter water level adjustment dial accordingly.

2. Possible Cause:Air inlet tube is blocked.

Solution: Remove and check for blockage and clean as required.

3. Possible Cause: Pump is not plugged in or is not operating correctly.

Solution: See pump section below

Problem: Skimmer water level fluctuates 

1. Possible Cause:The air intake port of the outlet pipe assembly is clogged causing the 

skimmer to create a siphon from the outlet tube.
Solution: Remove and check for blockage and clean as required.

Problem: Pump is not operating correctly
Caution:

Always isolate the pump from mains electricity before installing or carrying out any

maintenance to the pump and refer to the pump operation, maintenance and safety instructions
supplied with the pump.
1. Possible Cause: Pump is not plugged in.

Solution: Ensure pump is connected to power supply and switched on.

2. Possible Cause: Pump is blocked with dirt and debris.

Solution: Clean the pump to remove dirt and debris (refer to pump instructions for full
maintenance instructions).

Problem: No air bubbles (or very few) are being produced inside the skimmer

1. Possible Cause: The air tube to the venturi is not attached.

Solution: Re-attach venturi air inlet connection tube (11).

2. Possible Cause: The air inlet of the venturi chamber is clogged.

Solution: Remove and check for blockage and clean as required.

3. Possible Cause: Pump is not operating or performing correctly.

Solution: See pump section above and check pump position (see diagrams on p.3 & 4).

Problem: No foam is being produced inside the collection cup

1. Possible Cause:Water level inside the chamber needs to be adjusted.

Solution:Alter water level adjustment dial accordingly.

2. Possible Cause: Skimmer has just been installed and may take up to 24hrs to adjust

properly to aquarium system.
Solution: Let the pump run for 24-48 hours to allow the skimmer to establish itself.

Problem:Water is rapidly overflowing into the collection cup

1. Possible Cause: Water level may be too high.

Solution:Alter water level adjustment dial accordingly.

2. Possible Cause:Water is not being discharged through outlet hose assembly.

Solution: Remove and check for blockage and clean as required.

3. Possible Cause:V

2

Bubble Stop may need maintenance.

Solution: Clean or replace the V

2

Bubble Stop sponges.

7

Содержание V2Skim Series

Страница 1: ...the pump continues to maintain a steady water flow it must be cleaned regularly to ensure it does not become clogged with debris or detritus Pump rating 220 240V 50Hz unless marked otherwise Do not operate any appliance if it has a damaged cord or plug if it is malfunctioning or if it has been dropped or damaged in any way This unit is designed to be used indoors and is not suitable for any outdoo...

Страница 2: ...sembly part no 5365 7 Water Inlet 8 V2Skim Securing Screws part no 5369 sold separately 9 Main Skimmer Body 10 Venturi Injection Assembly 11 Venturi Air Inlet Connection Tube on models 800 1500 only part no 5370 12 Hanger 13 Venturi Air Intake Silencer on models 800 1500 only 14 Air Inlet 15 Collection Cup O Ring on models 600 1500 only part no 5364 16 Drain Port on models 800 1500 only 17 Collect...

Страница 3: ...mance do not locate the pump more than 20cm below the water inlet of the skimmer USEFULTIP Use the suction cup bracket provided with the pump to secure the pump on the side of your aquarium directly below the inlet of your V2Skim Protein Skimmer 4 Hang theV2Skim Protein Skimmer on the side of your aquarium in the desired location and tighten the securing screws 8 5 Connect pump to skimmer using th...

Страница 4: ...theV2Bubble Stop to be positioned in the desired location use two cable ties to secure the V2Bubble Stop to the upright fixed outlet pipe directly below the outlet see on Parts List diagram OPERATION 1 Make sure all connections are tightly secured 2 Ensure the skimmer collection cup 2 and lid 1 are securely and correctly positioned on the skimmer body 9 3 Turn the water level adjustment dial 3 to ...

Страница 5: ...outlet of the ozone generator to the air inlet 14 of the V2Skim Protein Skimmer using ozone resistant tubing not supplied the V2Skim s patented venturi injection system will automatically draw ozone gas into the main body of the skimmer USEFUL TIP Although ozone gas enhances the skimming process should a reduction in skimming performance be noticed following the addition of an ozone generator ther...

Страница 6: ...an and periodically replace the V2Bubble Stop sponges 8 Clean the pump regularly to ensure it does not become clogged with debris or detritus refer to pump instructions for full maintenance instructions 9 On models 800 1500 the venturi injection assembly 10 can be removed to allow easier cleaning and maintenance This is achieved by simply twisting the assembly clockwise and gently pushing downward...

Страница 7: ...tions for full maintenance instructions Problem No air bubbles or very few are being produced inside the skimmer 1 Possible Cause The air tube to the venturi is not attached Solution Re attach venturi air inlet connection tube 11 2 Possible Cause The air inlet of the venturi chamber is clogged Solution Remove and check for blockage and clean as required 3 Possible Cause Pump is not operating or pe...

Страница 8: ...ately 2400l hr V2Skim 600 For aquariums up to 600 litres 130 UK Gallons with a recommended flow rate of approximately 2400l hr V2Skim 800 For aquariums up to 800 litres 180 UK Gallons with a recommended flow rate of approximately 2800l hr V2Skim 1000 For aquariums up to 1000 litres 220 UK Gallons with a recommended flow rate of approximately 2800l hr V2Skim 1200 For aquariums up to 1200 litres 260...