TMC BLUE BELLE CHIC/TO Скачать руководство пользователя страница 8

 

2.8 Conduct in case of gas leaks

 

If you smell gas, proceed as follows! 
If you smell gas, do not ignite the device and close the cylinder valve by turning it clockwise. 
Do not touch any switch and do not use the phone. 
Open doors and windows to ventilate the room.  
Extinguish any flame or other potential ignition sources. 
No naked flames and no smoking.  
Carry out the test operations indicated in 3.4. Never carry out the test in the presence of naked flames.  
If there are no leaks, ignite the stove taking special care and in compliance with the instructions provided in 
the user manual. 
If  you  still  smell  gas,  try  to  replace  the  cylinder  as  the  gas  may  contain  an  excessive  amount  of  aroma 
compound. 
If the problem is not solved, contact the distributor or a specialized technician.  
Do not use the appliance until it hasn

’t been inspected by a qualified technician.  

Never attempt to make any repair work yourself. 
Failure to observe this warning may result in injuries or damage to property. 

 

3.  Preparing the appliance for operation

 

 

3.1 Opening the packaging

 

Upon delivery, check that the appliance is complete and in perfect conditions. 
If there are missing components or faults, do not use the product and contact the seller immediately. 
 

3.2 Keeping the original packaging

 

Keep the original packaging for the whole life of the appliance. 
Use the packaging to store and transport the appliance.  
Dispose  of  the packaging at the  end  of  the  life-cycle  of  the appliance.    For  further  information on  correct 
disposal, please refer to chap. 8. 
 

3.3 Connecting the stove to the gas bottle 

Never position the cylinder upside-down! 

When  connecting  the  cylinder  for  the  first  time,  and  any  time  the  cylinder  needs  to  be 
replaced, ensure that the room is well ventilated and that there are no naked flames. Do not 
smoke while carrying out these operations.  
If  the  cylinder  has  been  transported,  store  it  in  upright  position  for  at  least  1  hour  before 
using it. 
Ensure that the gas seal on the cylinder is intact and in perfect conditions. 
Check  that  the  connections  (the  regulator  ring  and  the  thread  on  the  cylinder  valve)  are 
clean and undamaged. 
Connect the cylinder outside the appliance, as illustrated here below:  
 

Read thoroughly before use. 
 

GB 

 
The following operations are required for the connection: 
- Only use this regulator on a Butane gas cylinder with a 21mm (G53) cylinder valve. 
- The LP nozzle outlet connection shall only be connected to 8mm Tubing to BS3212 Type 1, 8mm 
Hose to BS3212 Type 2, 8mm Tubing to BS EN 16436 Class 1, 8mm Hose to BS EN 16436 Classes 2 or 3. 
- The gas cylinder must always be in vertical position and the regulator must never be disconnected while 
the appliance is turned on. 
- Make sure that the hoses are kept clear of hot surfaces and inspect before use. Replace any hose that 
shows signs of wear, cracking or other damage. 
- In case of gas escape or malfunction, close the gas supply and contact your dealer. 
- Do not use a flame to test for gas leakage: Use a soapy water solution. 

Содержание BLUE BELLE CHIC/TO

Страница 1: ...class A A G THIS PRODUCT IS NOT SUITABLE FOR PRIMARY HEATING Instructions for use BLUE BELLE CHIC TO Free flame heater Household appliance Keep this manual for future reference Original in Italian SOB...

Страница 2: ...e WARNING AND SAFETY SECTIONS indicated by the symbol Warning Warning failure to comply with the information given in this manual may result in fire or explosions that may damage properties and injure...

Страница 3: ...packaging 3 2 Keeping the original packaging 3 3 Connecting the stove to the gas cylinder 3 4 Checking for leaks in the regulator 3 4 1 Checking for leaks in the regulator 3 5 Installing the gas cyli...

Страница 4: ...ved approval by the German certification body DVGW and complies with Gas European appliance regulation 2016 426 EU This stove is tested according to EU gas regulation as well as to EN 449 and complies...

Страница 5: ...the room is suitably ventilated and if the ODS system has triggered ventilate the room If you need to intervene too often this means that the room is too small or that ventilation is not sufficient M...

Страница 6: ...should only be allowed to use the appliance once they have been given the appropriate instructions The appliance is not intended to be used by persons children included with reduced physical sensory o...

Страница 7: ...1 2 m s ATTENTION Do not point fans directly toward the stove Avoid air currents that may change the flame of the burner When connecting the cylinder for the first time and any time the cylinder needs...

Страница 8: ...ispose of the packaging at the end of the life cycle of the appliance For further information on correct disposal please refer to chap 8 3 3 Connecting the stove to the gas bottle Never position the c...

Страница 9: ...until you hear a click NOTE The regulator can only be fitted to the cylinder valve when the control knob is in the OFF position Turning the regulator on After fitting the regulator correctly onto the...

Страница 10: ...position of the vent hole 6 Until the time of installation the product must be stored in a clean dry location protected from weather atmospheric agents and direct sunlight It must not be knocked or d...

Страница 11: ...nection Open the regulator knob Wait at least 20 seconds before opening the regulator again 2 In case of the flow of gas being higher than the capacity of the regulator contact your gas supplier Maxim...

Страница 12: ...the stove and contact your seller see chapter 6 Repair works or faulty component replacement must be carried out by qualified technicians who must use original components ATTENTION Ensure that the ga...

Страница 13: ...eplacing the cylinder ensure that the room is suitably ventilated Ensure that the gas valve is safely closed Do not use any tool to remove the pressure regulator just disconnect the regulator in accor...

Страница 14: ...he flame in the burner is yellow The gas cylinder is running low Dirty gas The room is very dusty When walking near the stove dust is sprayed around Replace the cylinder The flame slowly stabilizes on...

Страница 15: ...rranty period will be charged to the purchaser The warranty shall be invalidated in case of damages during transport or damages due to lack of care unintended use incorrect installation or failure to...

Страница 16: ...ce with the instructions and respecting the polarity The electronic ignition block contains an AAA type battery To replace the battery turn the top of the piezoelectric igniter see Fig 5 anti clockwis...

Страница 17: ...ve 2009 125 EU the regulations 2015 1186 EU 2015 1188 EU and in compliance with the harmonized standard EN 449 2002 A1 2007 and are subjected to EC type approval test Notified body CE 0085 has issued...

Страница 18: ...procedure s specified in the Regulation 2016 426 on gas appliances as brought into UK law and amended Annex III Module B Type Examination and issued the Certificates below UKCA Module B certificate UK...

Страница 19: ...heat output elmax x xxx kW single stage heat output no room temperature control No At minimum heat output elmin x xxx yes no two or more manual stages no room temperature control No In standby mode el...

Страница 20: ...diretta Direct power heat imput Potencia t rmica directa Direkte thermische Leistung Puissance thermique directe 4 2 kW e Potenza termica indiretta Indirect power heat imput Potencia t rmica indirect...