![TM Easytherm 1 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/tm/easytherm-1/easytherm-1_user-manual_1121541011.webp)
TM INDUCTION HEATING
11
ET 2.0 |
If in any doubt, isolate the induction heater and contact your local
distributor. You can find the contact details for your nearest distributor on
www.tminductionheating.com/distributors.
ERRORS
Magnetic temperature sensor is not
detected.
E01
The sensor is not plugged in /
Plug in the temperature sensor.
Environment temp. is too low (<0°C) /
Change location of induction heater.
The sensor is damaged /
Replace the temperature sensor.
Fatal hardware error.
E10
E12
The bearing is too heavy /
Check the max allowed weight.
The sensor is plugged in up side down /
Turn the temperature sensor plug around.
The cable of the sensor is broken /
Replace the temperature sensor.
The internal wiring is disconnected /
Contact your local distributor.
The bearing is too large /
Check the max allowed OD.
Isolate the induction heater and contact
your local distributor.
Code
Possible cause / Action
Event
E02
E03
The temperature increase is insufficient.
The increase was less than 1°C per
minute.