172-65168MA-04 (SA3) 1 Oct 2021
7
Maintenance
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
Be sure to use only the recommended components when repairing the
product, and NEVER attempt to modify the product in any way. Failure to
observe these precautions may result in damage to the product or burns
or other injury due to malfunction or the discharge of fluids.
CAUTION
Operational Check
A visual inspection of the following items should be done on a daily basis to
determine whether the air vent is operating properly or has failed.
If the air vent should fail, it may cause water leakage or hindrance to water flow.
Normal
: Air is discharged as it accumulates, with the air vent
closing (with no leakage) when no air is present in the
piping
Blocked
(Discharge Impossible)
: No air is discharged though air accumulates in the air
vent
Leakage
: Water is discharged or leaks through the air vent outlet
during closed position
Parts Inspection
When parts have been removed, or during periodic inspections, use the following
table to inspect the parts and replace any that are found to be defective.
Procedure
Body Gasket, O-ring
: Check for warping and damage
Valve, Valve Seat
: Check for scratches or wear