background image

 

172-65460MA-04  (JH7.5R-X)    20  Oct  2020

 

10

 

Disassembly/Reassembly of Components Inside the Body 

NOTE: The X-element case must be removed before the float can be removed. 

Part 

During Disassembly 

During Reassembly 

Snap Ring 
 

Pinch the insides together and 
remove from the body 

Insert securely into the groove in the body 

Screen 

Lift straight up and out while 
turning 

Place on the screen holder, making sure 
that the top of the screen does not stick 
up out of the body 

Screen Holder 
Retainer 

Remove without bending   

Place on the screen holder without tilting 

Screen Holder 

Remove without bending 

Place on the ledge inside the body, 
making sure the rounded side is on top 

Float 

Remove, being careful not to 
scratch the polished surface 

Insert, being careful not to scratch the 
polished surface 

Orifice Plug 

Remove with a box wrench 

Consult the table of tightening torques and 
tighten to the proper torque 

Orifice Plug 
Gasket 

Remove the gasket and clean 
sealing surfaces 

Replace with a new gasket; coat surfaces 
with anti-seize 

Orifice 

Remove with a box wrench 

Consult the table of tightening torques and 
tighten to the proper torque 

Orifice Gasket 

Remove the gasket and clean 
sealing surfaces 

Replace with a new gasket; coat surfaces 
with anti-seize 

Table of Tightening Torques 

Part Name 

Torque 

Distance Across Flats 

N

(lbf·ft) 

mm 

(in) 

Orifice 

600 

(440) 

46 

(1

13

16

Orifice Plug 

800 

(590) 

46 

(1

13

16

Cover Nut 

200 

(150) 

30 

(1

3

16

X-element Case 

150 

(110) 

50 

(1

31

32

Drain Plug   

100 

(73) 

26 

(1) 

NOTE:  -Coat all threaded portions with anti-seize. 

-If drawings or other special documentation were supplied for the 

product, any torque given there takes precedence over values 
shown here. 

(1 N

 10 kg

cm) 

 

Содержание JH7.5R-X

Страница 1: ...172 65460MA 04 JH7 5R X 20 October 2020 Free Float Steam Trap with X element JH7 5R X Copyright 2020 by TLV CO LTD All rights reserved ...

Страница 2: ...is steam trap is also of a revolutionary design featuring an integral air vent that employs a high performance X element The X element is very sensitive to changes in temperature and responds with great accuracy As a result air and the large quantities of condensate created immediately after the start up of operation are quickly discharged thereby greatly reducing start up time and also proving us...

Страница 3: ...oses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage WARNING NEVER apply direct heat to the float The float may explode due to increased internal pressure causing accidents leading to serious injury or damage to property and equipment CAUTION Install...

Страница 4: ... recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids Use only under conditions in which no freeze up will occur Freezing may damage the product leading to fluid discharge which may cause burns or other inju...

Страница 5: ... back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Has the piping work been done correctly as shown in the figures below Requirement Correct Incorrect Install catchpot with the proper diameter Diameter is too small Make sure the flow of condensate is not o...

Страница 6: ...lows for the rapid discharge of the air After the air is discharged and steam contacts the X element the temperature will increase causeing the air vent valve A to close 4 Discharge of Large Quantities of Condensate Increases in the condensate inflow rate cause the condensate level in the trap to rise The float consequently rises and enlarges the opening of the orifice B allowing more condensate t...

Страница 7: ...l Maximum Allowable Temperature TMA Maximum Allowable Pressure Maximum Operating Temperature Nominal Diameter Maximum Differential Pressure Valve No Production Lot No Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted from the nameplate when there are...

Страница 8: ...scharge of fluids CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before installation be sure to remove all protective seals 2 Before installing the product open the inlet valve and blow out the piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Ins...

Страница 9: ...products or losses due to steam leakage Normal Condensate is discharged continuously together with flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The trap is quiet and makes no noise and the surface temperature of the trap is low Blowing Live steam continually flows from the...

Страница 10: ...w gasket coat surfaces with anti seize Detaching Reattaching the Cover and its Components Part During Disassembly During Reassembly Cover Nut Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Cover Remove by lifting up and off Make sure there are no pieces of the old gasket left on the sealing surfaces of the body and cover align the arrows on the...

Страница 11: ...t being careful not to scratch the polished surface Orifice Plug Remove with a box wrench Consult the table of tightening torques and tighten to the proper torque Orifice Plug Gasket Remove the gasket and clean sealing surfaces Replace with a new gasket coat surfaces with anti seize Orifice Remove with a box wrench Consult the table of tightening torques and tighten to the proper torque Orifice Ga...

Страница 12: ...172 65460MA 04 JH7 5R X 20 Oct 2020 11 Exploded View ...

Страница 13: ...e affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads 5 Hold the plug holder upside down to make sure that the anti seize makes the gasket stick to the plug holder even when the plug holder is held upside down 6 Screw the plug holder by hand into the product body while making sure that the gasket remains tightly affixed to the ce...

Страница 14: ...e maximum specified pressure or whether there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks from the outlet blowing steam leakage Build up on the seating surface of the orifice or rust and scale build up beneath the float Clean parts Scratches on the orifice Replace with a new orifice The ...

Страница 15: ...roper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or inadequate inspection and maintenance by other than TLV CO LTD authorized service representatives 4 Malfunctions due to disasters or forces of nature 5 Accidents or malfunctions due to any other cause ...

Страница 16: ...MA 04 JH7 5R X 20 Oct 2020 15 Options The options shown below are available for this product on request Please compare with the product you received Options for Area A standard with drain plug Without Drain Plug ...

Отзывы: