5
FIGURE 14
Turn on the wall switch. The floodlight will turn on
for about 1 minute to warm up. Then it turns off.
Walk through the detection area. The floodlight
turns on when you move and turns off when you
stop. Wait for the floodlight to turn off before
moving again to test the sensor.
Adjust the motion sensor sensitivity to cover the
desired detection area. For a smaller coverage
area, tilt the sensor down; for a larger coverage
area, tilt the sensor up.
(2) TIME ADJUSTMENT
The TIME adjustment controls how long the floodlight
will stay on after the motion has been detected.
Turn the TIME control knob clockwise to increase (up
to about 12 minutes) how long the floodlights stay on
or anti-clockwise to decrease (down to about 8
seconds) the time delay (FIGURE 15).
FIGURE 15
(3) LIGHT ADJUSTMENT
The LIGHT adjustment adjusts the sensitivity and
determines what light level the lighting system will
start operating when you set the sensor to Automatic
Operation.
Provisionally turn the LIGHT control knob fully
clockwise to the moon (dusk) position (FIGURE 16).
In this provisional setting mode, the motion sensor
remains inactive during daylight. At dusk when you
have the LUX level desired for operation, simply set
the LIGHT control knob to the position that activates
the lighting system.
FIGURE 16
6
OPERATION
By using the wall switch connected to your motion
sensor floodlight, you can easily select one of two
modes of operation: Automatic Operation and Manual
Override.
(1) AUTOMATIC OPERATION
Turn on the wall switch. When the motion sensor
detects motion, the light automatically turns on. The
built-in photocell sensor turns the motion sensor off
and on according to the light level set by the LIGHT
adjustment.
(2) MANUAL OVERRIDE
To keep the light on regardless of the motion, you can
override the Automatic Operation. By turning the wall
switch OFF and ON twice within 4 seconds (the
interval between the first and second operation must
be within 0.5 - 2 seconds), the light will remain on in
manual override mode.
In Manual Override mode, the light will remain on for
around 4 ~ 6 hours despite no motion; then the light
will be reset back to Auto Operation mode
automatically.
Users can also set the motion sensor back to Auto
Operation by turning off the wall switch for at least 10
seconds and then turning back on.
TROUBLESHOOTING
Light does not turn on
Confirm that you have made a correct “wiring
connection”.
Make sure that the lamp has not burnt out.
Check if the fuse has blown.
Light remains on
Make sure the wiring connection is correct.
Check if the TIME setting is correct.
Check if the LIGHT (Lux) setting is correct.
Ensure that the PIR sensor is not being
continually activated by a heat/movement source.
SPECIFICATIONS
Power Requirement
AC 220 ~ 240V / 50Hz
Power Cord
Requirement
H05RN-F, 3G, 1.0mm²
Lighting Load
Max. 150W Halogen Lamp
for SEC150.
Max. 500W Halogen Lamp
for SEC500
Detection Angle
Up to 200
°
at 20
°
C
Detection Distance
Up to 12M at 20
°
C
Swiveling Angle
Lamp Part: Vertical 90°
Sensor Part: Horizontal
190
°
, Vertical 35
°
Mounting Height
Recommended 1.8 ~ 2M
(5.9 ~ 6.5 Ft) Wall Mount
Wall Switch Control
On / Off
Time Adjustment
8 sec ~ 12 min
Lux Adjustment
Approx. 5 ~ 1000 lux
Warm Up Time
About 1 min
Protection Class
Class I