![TKOKO AP-815E Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/tkoko/ap-815e/ap-815e_operation-manual_1121113002.webp)
POWER
VOLUME
REC LEVEL
PLAY
SIREN
PLAY
MSG
REC
MSG
START
REC/PLAY
STOP
REC/PLAY
MANUAL
ALARM
AP-815E
EMERGENCY PANEL
AP-815E Emergency Panel
Emergency Panel AP-815E is used in a public address system to produce an
alarm sound either by a short-circuit signal to trigger auto-alarm or by a manual
pushbutton. It can output a built-in siren signal or a user-recorded voice alarm
or siren. With the built-in 60-second digital recording IC, users may record their
own voice alarm or siren. This unit is designed to work with the AP-810P Paging
Selector, AP-811P Pre-Amplifier, and AP-813D Speaker Selector.
1
Front Panel
3
4 5
6
7
8
9
10
2
1 Power Switch
2 Power Indicator
6
FIRE: manual alarm button
7 START: starts recording or
playback
8 STOP: stops recording or
playback
9 Volume Control
10 Record Level Control
INPUT
OUTPUT
MIC
LINE
ALARM
WARNING!
CAUTION!
TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE
RISK OF
ELECTRIC SHOCK
DO NOT OPEN
115 V
230 V
24VDC
-
+
+
115/230V AC
50/60Hz
FUSE 0.5A
5
6
7
5
¡¢
DC 24V connection
6
¡¢
AC 115/230V switch
7
¡¢
AC Fuse
1
Mic for record
2
Line in for record
3
Alarm active input
4
Alarm audio output
Rear Panel
3
SIREN: outputs the
Siren the siren sound
4
PLAY: outputs the
Recording
5
REC: records the voice
message
Specifications
4
1
MODEL
AP-815E
MIC IN
<5mV , 600 ohms(
),IMBALANCE
LINE IN
<400mV , 10k ohms(
),IMBALANCE
LINE OUT
>200mV (SIREN OR RECORD)
FREQUENCY RESPONSE
100 Hz ~ 3.4k Hz (
3 dB)
THD
<0.01% at 1kHz
ADC/DAC
SAMPLE FREQUENCY:8k Hz 5 Bit
RECORD TIME
1 MINUTE(CAN BE EXTEND TO 2 MINUTES AND
100000 TIMES RE-RECORD)
SAVABLE RECORDS
3 ~ 5 RECORDS, DEPENDS ON THE RECORD TIME
FOR EACH
ALARM ACTIVATE IN
1
ALARM
ACTIVATE
ELECTRIC LEVEL
(0V)SHORT CIRCUIT SIGNAL
FUNCTION CONTROL
1 POWER SWITCH,6 MANUAL CONTROL
BUTTONS(SIREN,PLAY,REC, FIRE,START,STOP) ,1
OUTPUT VOL CONTROL,1 REC VOL CONTROL
INDICATOR
POWER
,
SIREN
,
PLAY ,
REC
,
FIRE
,
START ,
STOP
PROTECTION
AC FUSE
0.5A
1
POWER CABLE
TWIN(3
0.5 mm
2
)
1.5M (STANDARD)
POWER
AC
AC 115/230V
10% 50-60Hz (CHANGE THE POWER
INTO 115V OR 230V BY115/230V SWITCH BEFOR
USING)
POWER DC
DC 24V (CHANGE THE POWER INTO RIGHT
POLARITY BY INTERNAL PARTS OF MACHINE
BEFORE USING)
AC POWER CONSUMPTION
230V
5~10W
115V 5-10W
DC POWER CONSUMPTION
24V
3-10W
MACHINE SIZE
89(H)
483(W)
366(D) mm
CARTON SIZE
185(H)
520(W)
435(D) mm
G WEIGHT
7.78kg
N WEIGHT
6.08kg