User Manual - Network Bullet - TKIB41M1S & TKIB42M1S
EN
25
Parameter
Meaning
Configuration Method
TRANSI.(N-
>D)(dB)
It determines the night-to-day
switching in auto mode. When the
system gain is smaller than the value
of this parameter, the system enters
the day mode.
This parameter is valid in auto mode.
The value of
TRANSI.(D->N)
must
be greater than the value of
TRANSI.(N->D)
.
[Setting method]
Drag the slider.
[Default value]
30
Delay(s)
The delay time of day to night or
night to day.
This parameter is valid in auto mode.
[Setting method]
Drag the slider.
[Default value]
0
IR LED
z
Auto
: The infrared lamp is
enabled or disabled based on the
external environment identified
by the light dependent resistor
(LDR).
z
ON
: The system enters the night
mode forcibly.
z
OFF
: The infrared lamp is
disabled. The filter and image
color are switched based on the
external environment identified
by the LDR.
This parameter is valid in auto mode.
[Setting method]
Select a value from the drop-down list.
[Default value]
Auto
Strength
Strength of IR LED, as the value
increases, the image becomes
brighter.
[Setting method]
Drag the slider.
[Default value]
50
DTN Time
Time of day to night.
[Setting method]
Select a value from the drop-down list.
[Default value]
18:00
NTD Time
Time of night to day.
[Setting method]
Select a value from the drop-down list.
[Default value]
6:00