7-49
Install the unit
Any action performed on the unit which is not described in this manual may damage it.
Make sure that the installation surface can support at least four times the weight of the
unit in normal operating conditions. In case of excessive external stress (vibration,
strong winds or impact, for example), the equipment may need additional means of
protection.
Proper stainless-steel hardware should be carefully chosen to fasten the unit to the
surfaces. Proper tools should be used during the installation, in accordance to
environmental requirements.
Use caution when lifting and assembling the unit. It is recommended that non-slip
protective gloves be worn during installation. The unit could bear sharp edges.
Electrical connections (such as plugs and cords) must be protected from potential
hazardous environmental factors (e.g. foot traffic, hitting objects).
Open only the covers pointed out in this installation manual. Other covers should be
opened only by the manufacturer.
Use appropriate tools for the purpose. The particular nature of the site where the device
is to be installed may require special tools for installation.
Pointing the camera at the sun may damage it.
Complete the installation performing the camera connection referring to the manual of
the camera.
After the installation of the unit, the desiccant bag must be placed inside the camera,
assuring it won't be damaged by rotating and moving parts.
Carefully check the supply voltage marked on the label. An incorrect power supply
voltage may damage the unit. Do not overload the terminal connection, as it may cause
a fire or electrical shock hazard.
Earth ground attachment point is a stud M4-0.7 x16 A4-70 ISO 4762 with dual nut and
dual serrated washer.
During installation it is important to connect it to an appropriate grounding location using
a (minimum) 10 AWG copper stranded wire.
An all-pole mains switch with an opening distance between the contacts at least 3 mm
in each pole must be incorporated in the electrical installation. The switch must be
equipped with protection against the fault current towards the ground (differential) and
the overcurrent (magnetothermal, maximum 15 A). Recommended for 115 Vac / 230
Vac: 2 A Delayed Fuse T (Time delay) or equivalent resettable devices such as
magnetothermal. Recommended for 24 Vac: 4 A Delayed Fuse T (Time delay) or
equivalent resettable devices such as magnetothermal. These ratings include inrush
current for startup or temporary overload. It must be very quickly recognizable and
readily accessible. Install a suitable overcurrent protection.
For connection to the mains, use a multipolar cable having minimum 3x1,5 mm2 (15
AWG). The mains cable must be protected.