TJERNLUND IN-FORCER PAI-3 Скачать руководство пользователя страница 4

MULTIPLE APPLIANCE CONTROLS
MODELS MAC1E & MAC4E
Used with any UC1 controlled Inducer
to interlock additional 24/115 VAC
heaters.  Powered by and communi-
cates with the UC1 through a factory
wired whip. For one additional 24/115
VAC heater add the MAC1E. To inter-
lock up to four more additional 24/115 VAC heaters, add
the MAC4E.  MAC4Es can be daisy chained together for
more than 5 heaters. Important: Total combined BTU/hr.
input of all heaters and total equivalent pipe lengths
must be within Inducer’s capacity.

MILLIVOLT HEATER INTERLOCK
MODEL WHKE
For use with UC1 Universal Control,
MAC1E or MAC4E auxiliary controls.
The WHKE gas pressure switch actu-
ates the Inducer through the A - B dry
contacts.  The Linear Limit switch dis-
ables the heater in the event of a
venting malfunction.  Includes JA1
thermocouple junction adapter. To
interlock millivolt water heater(s) only with a UC1
controlled Inducer add a WHKE for each millivolt heater.
To interlock a millivolt water heater and one 24/115 VAC
furnace or boiler with a UC1 controlled Inducer, add a
WHKE and a MAC1E.

VENT HOODS
MODELS VH1-3", 4", 6", 8", 10"
Specially designed to terminate
Tjernlund Side Wall Vent Systems.
They are also an approved method
of terminating many horizontally
vented appliances. Vent Hoods
feature heavy duty, corrosive
resistant aluminum construction.
Models VH1-3, 4, 6 also feature
built in clearances from com-
bustibles. Building exteriors are
kept clean while the aesthetics of the structure
remain undisturbed. All mounting hardware is included.

BAROMETRIC DRAFT CONTROLS
MODELS DC4 THRU DC10

DC4G THRU DC10G

Quality engineered and manufactured
to maintain a consistent draft on a
wide range of oil and gas fired heating
equipment. May be used with chimney
vented or power vented heating equip-
ment. For fan assisted gas, oil or solid
fuel applications with vent diameters
from 4-10" choose the DC4 thru DC10.
For LP and Natural gas applications
with vent diameters from 4-10", choose the DC4G
thru DC10G.

DUCT BOOSTER

®

FAN

MODEL DB-2
Tjernlund’s Duct Booster is the ORIGINAL
money saving and energy efficient residential
booster fan. It increases the comfort level in
hard to heat or cool areas. No need to adjust
the whole house thermostat or install auxil-
iary heating/cooling equipment. Fits round or
flat forced air heating/cooling ductwork.
DB-2 features: easy installation, durability,
economical price and manual or automatic
operation. Boosts air flow up to 275 CFM.

DUCT BOOSTER

®

FANS

MODELS EA-5, EF-6, EF-8, EF-10, EF-12, EF-14
Residential and Commercial Duct
Booster fans boost air flow and
increase  the comfort level in hard to
heat or cool rooms. Eliminates the
need to adjust the thermostat or
install auxiliary heating or cooling
equipment. Fans can also be used
for exhaust or fresh air intake appli-
cations. Fits into metal or flex duct.
Models feature: easy installation,
durability, economical price, variable speed adjustability, manual or
automatic operation. Capacities from 180 CFM up to 1200 CFM.

HIGH PRESSURE DUCT BOOSTER

®

/ EXHAUST FANS

MODELS P-4, P-6, P-8, M-4, M-6, M-8
Residential and Commercial M-Series
(Metal) and P-Series (Plastic) fans are our
most versatile and durable fans featuring
high pressure air handling performance,
low noise and low power usage. M-Series is
ideal for long runs or air supply and exhaust
applications requiring exacting perform-
ance. P-Series are the ultimate bath-
room/spa exhausters and also work great for radon mitigation and
dryer vent boosting. Units feature: easy installation, maintenance
free operation, variable speed adjustability, backward inclined
wheel and external rotor motor. Capacities from 125 to 500 CFM.

SANTEK ELECTRONIC AIR CLEANERS
MODELS SP-1200, SD-1000, SX-2000
Available in three models from 1,000 to
2,000 CFM. Air cleaners remove particles
down to .01 microns capturing smoke,
dust, pollen and bacteria with up to
95% efficiency. Air change requirements
may be reduced when electronic air
cleaners are used to reduce airborne pollutants. All models feature
extra heavy-duty collecting cells and activated carbon filters for
odor control. Model SP-1200 features recessed mounting, a low
noise internal rotor motor and 3 speed operation. Model SD-1000
has 1 collecting cell and 3 speed operation. Model SX-2000 has 2
collecting cells and 3 speed operation.

TJERNLUND PRODUCTS, INC.

1601 Ninth Street    White Bear Lake, MN 55110-6794     
Phone: 651.426.2993     800.255.4208     Fax: 651.426.9547
Visit our web site: www.tjernlund.com  

Copyright © 2005 Tjernlund Products, Inc.   All rights reserved.     P/N 8500669    Rev. D 06/05

Available From:

Содержание IN-FORCER PAI-3

Страница 1: ...water heater manufacturers provide us with a working knowl edge of their product requirements that we use to develop solutions to real world draft combus tion air and ventilation problems Tjernlund products perform and endure through tough environments because we take pride in engineering and manufacturing to the highest quality standards Our microprocessor based controls have user selectable oper...

Страница 2: ...LIVOLT GAS WATER HEATER VENTING PACKAGES MODELS VP 2 VP 3 For side wall venting millivolt gas water heaters Excellent for electric to gas conversions renovations new construction or for replacing old chimneys Vents up to 75 equiv alent feet and includes Post Purge Relay Timer 24V Solenoid Valve Gas Pressure Switch Spill Switch and Vent Hood Factory prewired electrical box and 24V Control Cables el...

Страница 3: ...nal strips By adding EXP 4E expansion modules up to 16 individual heaters can be interlocked AUTO DRAFT INDUCED DRAFT SYSTEMS MODELS FSAD8 115 FSAD10 115 FSAD12 230 VSAD8 230 or 460 VSAD10 230 or 460 VSAD12 230 or 460 Exterior mount Variable or Fixed Speed Auto Draft Inducers reduce vent diame ters up to 50 overcome convoluted vent layouts dramatically shorten stack height above roof line Suitable...

Страница 4: ...No need to adjust the whole house thermostat or install auxil iary heating cooling equipment Fits round or flat forced air heating cooling ductwork DB 2 features easy installation durability economical price and manual or automatic operation Boosts air flow up to 275 CFM DUCT BOOSTER FANS MODELS EA 5 EF 6 EF 8 EF 10 EF 12 EF 14 Residential and Commercial Duct Booster fans boost air flow and increa...