8. Use a flathead screw driver to adjust the temperature setting of the thermostat switch to the desired activation 

temperature. The fan will operate once that temperature is reached and run until the garage is approximately 20F cooler 
(see chart below). 

Note: 

The switch is sensing the temperature at the location of the switch (the bottom part of the attic), so adjust the setting
slightly higher than the temperature you would like to maintain in your garage.

9. Secure the fan intake grille against the ceiling of the garage so the louvers face the intake 

grilles. Align the holes of the grille and theholes of the intake plenum (Figure J).

10. Cut 12” x 12” holes in your garage door or garage walls and mount the included in fresh air 

intake grilles to allow outdoor air to enter the garage space as the fan operates (Figure K). 
Make sure the added depth of the grilles clears the top frame of the garage door

11. Position grilles over the opening ensuring the louvers face downward to prevent rain from 

entering the garage. Mark mounting holes and drill small pilot holes.

12. Mount grilles with provided screws. Do not overtighten screws. Tighten just so the screw 

head meets the grille.

REPLACEMENT PARTS 

Component

Part Number

Component

Part Number

Motor Kit

950-0423

Ceiling Radiation Damper

950-3371

Impeller Kit

950-0421

Thermostat Switch

950-3372

Fan Intake Grille

950-3370

Garage Door Grille

950-3373

WARRANTY 

70

80

90

100

110

120

CUTOFF TEMPERATURE (BREAK)

130

CB14 PERFORMANCE

75

85

95

105

115

125

135

70

80

90

100

110

120

SET TEMPERATURE (MAKE)

130

75

85

95

105

115

125

135

65

65

SMALLER
RANGE
TOWARDS
LOW

LARGER

TEMPERATURE

RANGE TOWARDS

THE HIGH END

END

TJERNLUND LIMITED ONE YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material
or  workmanship  for  a  period  of  (1)  year  from  the  date  of  original  purchase  or  delivery  to  the  original  purchaser,  whichever  is  earlier.
Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated war-
ranty  period,  be  returned  to  Tjernlund  Products,  Inc.  at  the  address  listed  below,  postage  prepaid.    THERE  ARE  NO  WARRANTIES
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DIS-
CLAIMS  LIABILITY  FOR  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES  ARISING  FROM  THE  USE  OF  THIS  PRODUCT.    THIS
WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY
LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY.  IMPLIED WARRANTIES ARE LIMITED TO THE
STATED DURATION OF THIS LIMITED WARRANTY.  Some states do not allow limitation on how long an implied warranty lasts, so
that limitation may not apply to you.  In addition, some states do not allow the exclusion or limitation of incidental or consequential dam-
ages, so that above limitation or exclusion may not apply to you.  This warranty gives you specific legal rights and you may also have
other rights which may vary from State to State.  Send all inquiries regarding warranty work to Tjernlund Products, Inc. 1601 9th Street,
White Bear Lake, MN 55110-6794.  Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 • Email [email protected].

Figure J

Figure K

Содержание Cool Breeze CB14

Страница 1: ...e is found notify freight carrier and your distributor immediately and file a concealed damage claim OPERATION The CB14 can be wired to be controlled manually by a wall switch not included by the included temperature switch or both Also available from Tjernlund are wall mount timers P N 950 9300 and wireless wall switches P N SWS Contact Tjernlund for more information on these controls INSTALLATIO...

Страница 2: ... paths to gable ridge or roof vents 1 Outline a 16 x16 square on your garage ceiling at the desired fan location considering the above points 2 Cut along outline with drywall knife to create hole opening Figure A 3 Intake plenum can be pushed up into the hole and secured from the garage Figure B or placed on ceiling from attic and secured from above Figure C Center the intake plenum along opening ...

Страница 3: ...m Secure both mounting bracket ends to the truss or joist Repeat on the other side of the intake plenum 4 Manually insert crimped end of fan into the radiation damper Drill 1 8 holes through both the radiation damper and fan on the 4 sides of the fan assembly damper and fan Figure G Secure the radiation damper to the fan using the 4 included screws Figure H 5 Place fan assembly damper and fan onto...

Страница 4: ...ATURE MAKE 130 75 85 95 105 115 125 135 65 65 SMALLER RANGE TOWARDS LOW LARGER TEMPERATURE RANGE TOWARDS THE HIGH END END TJERNLUND LIMITED ONE YEAR WARRANTY Tjernlund Products Inc warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of 1 year from the date of original purchase or delivery to the original p...

Страница 5: ...6 10 13 GREEN N L1 RED RED WHITE BLACK TIMER SWITCH 10 MIN 20 MIN 30 MIN 60 MIN OFF BLACK WHITE GREEN RED T STAT BLACK WHITE CB14 TEMPERATURE CONTROLLED FIGURE 8089018 6 5 13 GREEN RED RED WHITE GREEN RED N L1 T STAT CB14 CONTROLLED BY ANY SWITCH FIGURE 8089019 6 17 13 GREEN N L1 RED RED WHITE BLACK SWITCH MUST BE RATED TO 5 AMPS 115 VAC ...

Страница 6: ...3 GREEN RED RED WHITE BLACK N L1 REMOTE OFF ON RED SMOOTH BLACK RED BLACK RIBBED ANTENNA TO MOTOR STRETCHED VIEW SWITCH IT WIRELESS RECEIVER T STAT CB14 SWITCH IT CONTROLLED FIGURE 8089024 6 13 13 GREEN RED RED WHITE BLACK N L1 REMOTE OFF ON RED SMOOTH BLACK RED BLACK RIBBED ANTENNA TO MOTOR STRETCHED VIEW SWITCH IT WIRELESS RECEIVER T STAT CB14 TEMPERATURE AND MANUALLY CONTROLLED FIGURE 8089023 6...

Отзывы: