Titus T3SQ Скачать руководство пользователя страница 2

For system balancing, the springs (A) must be 

disconnected from the control disc (B) to allow the 

control disc to go to full open. (See Figure 2)

After balancing, reconnect the springs to the control 

disc. If the actuator arms are not connected to the 

control disc the diffuser will not operate.

Ensure that each control disc spring (A) is attached 

to both the control disc (B) and the lever arm (C) 

before installing.

T3SQ-4-IOM-3.0

05-17-07

Figure 4.

T

3

SQ-4 Operating Instruction  Label

Note: This IOM is meant to demonstrate general dimensions of this product. The drawings on this IOM are not meant to detail every aspect of the product with exactness. Drawings are not to scale. 

TITUS reserves the right to make changes without written notice.

Step 3

Step 4

Place the back pan into ceiling grid. Connect duct 

work to back pan.

Step 2

Adjust room temperature:

Turn the blue ring assembly (D) to the desired 

temperature indicated ( 66°F to  74°F)

To adjust the offset differential between heating 

and cooling, turn the green tab (E) clockwise to 

increase positive temperature offset and 

counterclockwise to increase temperature offset in 

a negative direction.

Step 5

Installation is completed by lining up the hooks on 

the face plaque assembly with the corresponding 

slot. The hooks are inserted and the face plate 

assembly is rotated clockwise, and lowered so 

that each hook is firmly in place. (See Figure 3)

Step 6

Minimum airflow can be adjusted from 30% of 

maximum down to fully closed or 0% of maximum 

by turning the grey flow adjustment ring (F) 

clockwise.

Figure 2.

T

3

SQ Thermal Actuator and Control Disc Assembly

Figure 3.

Face Plaque Installation

A simplified version of these operating instructions 

can be found on the plaque of each diffuser. 

(See Figure 4) 

Note:

Thermal - T

3

SQ-4 Replacement Parts

Description

Part Number

A

B

E

D

F

C

3.

1.

2.

Heating / Cooling Actuator

Venturi Tube

Venturi Tube Guide

Control Disc Sleeve

Control Disc

Thermal Induction Channel

Induction Cap

Plaque/Actuator/Control Disc Assy T3SQ-4

38203201

72540201

72540301

72540401

72540501

78200201

72549501

31763101

All rights reserved. No part of this work may be reproduced or transmitted in any form or any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies.