VIBRATION

The European Physical Agents (Vibration) Directive has been brought in to help reduce 

hand arm vibration syndrome injuries to power tool users. The directive requires power 

tool manufacturers and suppliers to provide indicative vibration test results to enable users 

to make informed decisions as to the period of time a power tool can be used safely on a 

daily basis and the choice of tool.

Further Advice can be found at www.hse.gov.uk

 

T

he declared vibration emission value should be used as a minimum level and should be used 

with the current guidance on vibration.

Calculating the actual period of the actual period off use can be difficult and the HSE website has 

further information.

The declared vibration emission been measured in accordance with a standardised test stated 

above and may be used to compare one tool with another.

The declared vibration emission value may also be used in a preliminary assessment of exposure.

          Warning: 

T

he vibration emission value during actual use of the power tool can differ from 

            the declared value depending on the ways in which the tool is used dependant on the 

following examples and other variations on how the tool is used:

How the tool is used and the materials being ground or cut.

The tool being in good condition and well maintained

The use the correct accessory for the tool and ensuring it is sharp and in good condition.

The tightness of the grip on the handles.

And the tool is being used as intended by its design and these instructions.

This tool may cause hand-arm vibration syndrome if its use is not adequately

managed

          Warning: 

identify safety measures to protect the operator that are based on an 

             estimation of exposure in the actual conditions of use (taking account of all parts of the 

operating cycle such as the times when the tool is switched off and when it is running idle in 

addition to the trigger time).Note The use of other tools will reduce the users’ total working period 

on this tool.

Helping to minimise your vibration exposure risk.

Maintain this tool in accordance with these instructions and keep well lubricated (where 

appropriate)

Avoid using tools in temperatures of 10°C or less

Plan your work schedule to spread any high vibration tool use across a number of days.

Health Surveillance

All employees should be part of an employer’s health surveillance scheme to help identity any 

vibration related diseases at an early stage, prevent disease progression and help employees stay 

in work.

Vibration total values (triax vector sum) determined according to EN 60745:

Grinding

Vibration for angle grinding a

h, AG

 

= 7,777m/s

2

Uncertainty K 

= 1,5m/s

2

Vibration for auxiliary handle a

h, AG

 

= 6,723 m/s

2

Содержание TTB281GRD

Страница 1: ...ANGLE GRINDER 750W TTB281GRD SAFETY AND OPERATING MANUAL Original instructions V3 0...

Страница 2: ...RANTEE This product carries a guarantee 2 years If your product develops a fault within this period you should in the first instance contact the retailer where the item was purchased This guarantee sp...

Страница 3: ...grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or...

Страница 4: ...and or the battery pack from the power tool before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accide...

Страница 5: ...the power tool will run out of balance vibrate excessively and may cause loss of control g Do not use a damaged accessory Before each use inspect the accessory such as abrasive wheels for chips and cr...

Страница 6: ...nching Abrasive wheels may also break under these conditions Kickback is the result of power tool misuse and or incorrect operating procedures or conditions and can be avoided by taking proper precaut...

Страница 7: ...ck may occur Investigate and take corrective action to eliminate the cause of wheel binding d Do not restart the cutting operation in the workpiece Let the wheel reach full speed and carefully re ente...

Страница 8: ...grinding or metal wheels on masonry 21 Watch out for flying sparks When grinding hold the tool at an angle of approximately 15 to 30 to the workpiece surface 22 Let the disc do the grinding or cuttin...

Страница 9: ...ent of Asthma The risk of lung disease is linked to people who regularly breathe construction dust over a period of time not on the odd occasion To protect the lung the COSHH Regulations sets a limit...

Страница 10: ...cut The tool being in good condition and well maintained The use the correct accessory for the tool and ensuring it is sharp and in good condition The tightness of the grip on the handles And the too...

Страница 11: ...ctive Double insulation The tool is double insulated This means that all the external metal parts are electrically insulated from the mains power supply This is done by placing insulation barriers bet...

Страница 12: ...1 Spindle lock button 3 Auxiliary handle 2 Double action on off switch 4 Cutting guard 5 Cutting disc 6 Guard release lever 7 Grinding guard 8 Spanner 1 5 7 8 6 4 3 2...

Страница 13: ...Protection class Machine weight II 2 2kg ACCESSORIES Auxiliary handle 1pc Spanner 1pc 115mm cutting guard 1pc 115mm grinding guard 1pc 115mm metal cutting disc 1pc NOISE DATA Wear ear protection when...

Страница 14: ...and then release it See Fig 3 4 REPLACING THE GUARD Fig 4 Fig 5 Depending on whether your operation is cutting or grinding select the correct disc guard This tool is supplied with both grinding and c...

Страница 15: ...rse these instructions Warning the spindle lock button must only be used when changing a disc Never press when the disc is rotating Always ensure your disc is securely clamped WORKING HINTS FOR YOUR A...

Страница 16: ...ormal If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Always handle abrasives with great care they are...

Страница 17: ...truction below IMPORTANT The wire in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live The wire that is coloured blue must be connected to the terminal that is...

Страница 18: ...DER 750W Model TTB281GRD Complies with the following Directives 2004 108 EC Electromagnetic Compatibility Directive 2006 42 EC Machinery Directive 2006 95 EC Low Voltage Directive 2011 65 EU Restricti...

Отзывы: