PLUG REPLACEMENT
If you need to replace the fitted plug then follow
the instructions below.
IMPORTANT
The wires in the mains lead are coloured in
accordance with the following code:
Green & yellow ---Earth
Blue ---Neutral
Brown ---Live
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows. The wire which is
coloured
green & yellow
must be connected to
the terminal which is marked with E or .
The wire which is coloured blue must be
connected to the terminal which is marked
with
N
. The wire, which is coloured brown,
must be connected to the terminal, which is
marked with the letter
L
.
WARNING: Never connect live or netutral
wires to the earth terminal of the plug. Only fit
an approved 13 Amp BS1363/A plug and the
correct rated fuse.
Note:
If a moulded plug is fitted and has to be
removed take great care in disposing of the
plug and severed cable, it must be destroyed
to prevent engaging into a socket.
If the supply cord is damaged it must be
replaced by a service agent or a similarly
qualified person in order to avoid hazard.