Drill the holes and insert suitable wall plugs
Use a braddle to punch a small hole in the
mounting plate cable grommet, to allow the supply
cable to enter the mounting plate. FIGURE 4
FIGURE 4
Insert the supply cable through the grommet and
fix the mounting plate to the wall using
appropriate mounting screws.
WIRING INSTRUCTION
(1) WARNING isolate the power supply.
(2) An internal single pole wall switch is
recommended to allow easy control of the Globe
Light. FIGURE 5
(3) Connect the supply cable to the unit. FIGURE 5
Strip approximately 6-8mm of inner core
insulation from the supply cable.
(4) Connect the BROWN wire (Live wire) to the
terminal marked “L”.
Connect the BLUE wire (Neutral wire) to the
terminal marked “N”.
Connect the GREEN/YELLOW wire to the
terminal marked
FIGURE 5
(5) Fit the Globe Light to the mounting plate and
secure with the two nuts. FIGURE 6
FIGURE 6
LAMP INSTALLATION
The Globe Light is suitable for use with a maximum
lamp rating of either a 60w incandescent lamp or 13w
fluorescent lamp with ES27 caps.
(1) WARNING isolate the power supply or turn off
the wall switch.
(2) Turn the screws to the ‘Open’ position on the
underside of the metal globe support. (FIGURE 7).
FIGURE 7
(3) Lift off the glass globe and place carefully in a
safe place so it does not get damaged. FIGURE 8
FIGURE 8
(4) Insert the lamp into the lamp holder and turn
clockwise to secure it. Do not over tighten. FIGURE 9
FIGURE 9
(5) Refit the glass globe and support it in position
whilst you turn the screws to the ‘Close’ position on the
underside of the metal globe support.
SETTING UP
The PIR control cover can be adjusted to give the
detection distance you require. FIGURE 10
FIGURE 10