OPERATION OF THE GENERATOR
Starting the Engine - Recoil starting
CAUTION!
DO NOT start or stop the engine with electrical
loads connected to the receptacles. Be certain
connected devices are OFF before connecting
or disconnecting.
DANGER!
DO NOT run generator indoors or in poorly venti-
lated areas. Engine exhaust contains carbon
monoxide which is an odorless, deadly gas.
WARNING!
To avoid burns, avoid muffler and nearby areas.
Figure
#3
-
Fuel
Valve
Positions
Starting the Engine - Electric starting
off
on
Figure #4 - Compression Release Switch
Figure #5
1
. Be sure unit is at a level, well ventalated
position.
2.
Check fluid for proper levels
3.
Turn on fuel valve. (figure #3)
4. Put Throttle lever to the run position
(figure #5)
5
. Turn ignition key on control panel to the
run positon.
6.
Push and hold down the decompression
lever (figure #4)
Pull the recoil starter briskly until the engine is
rotating, then,
release lever.
7.
Let engine settle before attaching any appli-
ances
1.
Be sure unit is at a level, well ventalated position
2.
Check fluids for proper levels.
3
. Turn on fuel valve. (figure #3)
4.
Put Throttle lever in the run position
(figure #5)
5
. Turn the ignition key to the “Start” position
6.
Once engine has started return the key to
the “ON”
7
. Let engine settle before attaching any appliances
7
Содержание TG 6500D
Страница 11: ...Parts Catalog P O Box 791 Travelers Rest S C 29690 Phone 864 834 7212 Service Replacement Parts 800 845 4141 11...
Страница 17: ...6 Fuel Injection System These Parts Sold As Assemblies 17 Fuel Injector Fuel Pump...
Страница 20: ...20...
Страница 21: ...21 P O Box 791 Travelers Rest S C 29690 Phone 864 834 7212 Service Replacement Parts 800 845 4141 186...
Страница 22: ...22...
Страница 24: ...P O Box 791 Travelers Rest S C 29690 Phone 864 834 7212 Service Replacement Parts 800 845 4141...