background image

10 

APPLICATIONS 

 

1. Connect to a RS-232 port of computer 

 

The SER-4485-SI-M can convert RS-232 to RS-485 interfaces for extension to 4 highly 

reliable RS-485 interfaces. 

 

 

 

2. Connect to existing RS-485 bus 

 

The SER-4485-SI-M can connect to existing RS-485 bus for extension to 4 highly 

reliable RS-485 interfaces, and as many as 128 RS-485 hubs are supported on each RS-

485 bus. 

 

 

 

 

Содержание SER-4485-SI-M

Страница 1: ...SER 4485 SI M USER S MANUAL 2019 Edition Titan Electronics Inc Web www titan tw...

Страница 2: ...bited Disclaimer TITAN Electronics Inc provides this document and computer programs as is without warranty of any kind either expressed or implied including but not limited to its particular purpose T...

Страница 3: ...6 Installation 7 PIN OUT INFORMATION 9 Terminal Block TB3 Pin out 9 Terminal Block TB1 Pin out 9 APPLICATIONS 10 1 Connect to a RS 232 port of computer 10 2 Connect to existing RS 485 bus 10 3 Connect...

Страница 4: ...e The SER 4485 SI M is optically isolated with 3000VDC optical isolation The optical isolation protects your PC or RS 485 devices from spikes and surges on the RS 485 network by converting the electri...

Страница 5: ...485 bus downstream and upstream ports RS 232 and RS 485 input interface options Supports transmission data rate up to 230 4kbps Provides failure warning and protected circuit for four RS 485 downstre...

Страница 6: ...15kV Isolation 3000VDC Connection 6 pin terminal block for upstream 10 pin terminal block for downstream LED Indicators LEDs Power 1 PWR Red Port Status 2 TxD Green RxD Yellow Error Status 4 Err1 Err2...

Страница 7: ...6 HARDWARE SETTINGS Block Diagram of SER 4485 SI M...

Страница 8: ...D signal pin2 of DB9 and the GND pin to external RS 232 GND pin pin5 of DB9 For converting RS 485 to RS 485 hub connect the data cable to the Data Data in upstream ports of SER 4485 SI M You need to c...

Страница 9: ...ng to the failure indication LEDs Err1 indicates the RS 485 Bus1 Err2 the RS 485 Bus2 and so on The SER 4485 SI M power input is designed with a diode bridge circuit You don t need to care the input D...

Страница 10: ...lock connector slave Pin Number Pin Type Description 1 Data1 Input Output RS 485 Port 1 transmit receive data positive polarity 2 Data1 Input Output RS 485 Port 1 transmit receive data negative polari...

Страница 11: ...RS 232 to RS 485 interfaces for extension to 4 highly reliable RS 485 interfaces 2 Connect to existing RS 485 bus The SER 4485 SI M can connect to existing RS 485 bus for extension to 4 highly reliab...

Страница 12: ...5 interfaces for extension to more highly reliable RS 485 interfaces 4 Connect to existing RS 485 bus for more RS 485 devices The SER 4485 SI M can connect to existing RS 485 bus for extension to more...

Отзывы: