background image

9

INSTALLATION INSTRUCTIONS 

(CONTINUED)

Pump Float Assembly

Model SBA025T1, SBA033T1, and SBA050T1 are supplied with tether float assemblies which are attached to the pump.
Models SBA025V1, SBA033V1, and SBA050V1 are supplied with vertical float assemblies. These vertical float assemblies must 

be attached to the pump. Refer to the following diagram for assembly.

Installation for Proper Pump Operation

The pump MUST be secured in a manner that prevents the pump from moving. If the pump is allowed to move, the float 

switch could be restricted by the sump wall, preventing the pump from turning on/off. The minimum diameter sump hole 

should be no less than 356 mm [14”] for a tethered float and 254 mm [10”] for a vertical float. The minimum depth should be 

no less than 457 mm [18”] for tethered models and 356 mm [14”] for vertically switched models. The tether length should be 

no shorter than 76 mm [3”] for proper operation. Do NOT increase the tether length on the float switch to more than 127 mm 

[5”] tether or the pump will NOT turn off.
To allow the unit to deliver maximum capacity, the sump should be kept free of accumulated sediment. A 32 mm [1 ¼”] 

discharge pipe will give best performance for this pump. The vertical distance from the pump to the highest point of discharge 

piping should NOT exceed 6 m [20 ft.]. Keep trash or other objects from interfering with the float.

 

Pump and Piping

The pump and piping should be positioned securely so that the float will not hang up on the side of the sump, the power cord, 

or the discharge pipe. The discharge pipe should be 32 mm [1 ¼”]. A union should be installed to facilitate installation and a 

check valve is recommended to prevent water from draining back into the sump and increasing pump operating frequency. 

The discharge pipe should be routed to the point of disposal with a minimum number of elbows to reduce losses.
A rigid discharge pipe is recommended to prevent the pump from moving. If a flexible discharge hose is used, the pump hose 

MUST be secured in a manner that prevents the pump from moving. If the pump is allowed to move, the float switch could be 

restricted by the sump wall, preventing the pump from turning on/off.

Содержание DURO PROFESSIONAL Series

Страница 1: ...in property damage injury and or death CanatureWaterGroup Canada Inc Canature did not design or manufacture this product Canature has no knowledge of and makes no representations or warranties respecting the product s design manufacturing testing packaging or inspecting Canature has disclosed all known risks associated with the product within this manual but cannot disclose risks that are beyond i...

Страница 2: ...Before Installing or Operating Pump 8 Sump Hole 8 Pump Float Assembly 9 Installation for Proper Pump Operation 9 Pump and Piping 9 Pump Operations 10 Electrical Information 10 AutomaticThermal Overload Protection 10 Maintenance Instructions 11 Cleaning the Pump 12 Troubleshooting Checklist 13 WARRANTY 14 Additional Limitations 15 Notice to Consumer 15 ...

Страница 3: ...ughout this manual certain conventions are used including Hazard symbols For your own safety please pay strict attention Examples include Hazard signals indicate the degree of harm that will or may occur look like those below Temperature White lettering with red background safety alert symbol Black lettering with orange background safety alert symbol Black lettering with yellow background safety a...

Страница 4: ... warranty Please read all information and instructions before installing the pump Failure to consider this information and follow these instructions may result in property damage injury and or death Indicates a hazardous situation which if not avoided will result in death or serious injury and or property loss or damage Indicates a hazardous situation which if not avoided could result in death or ...

Страница 5: ...n investigated for use in swimming pool or marine areas WARNING RISK OF ELECTRIC SHOCK Do NOT use the power cord to remove or lower the pump into the basin The cord may pull apart exposing bare wires which could cause a fire or electrical shock Use the handle supplied with the pump for installing and removing the pump from the basin WARNING Running the pump dry will void the warranty Do NOT run th...

Страница 6: ...e performed by a qualified electrician WARNING RISK OF SUCTION To prevent injury never insert fingers into pump while it is plugged in WARNING Basins must be vented according to local plumbing codes WARNING Do NOT handle this pump with wet hands or while standing in wet or damp surfaces or in water WARNING If a flexible discharge hose is used make sure the pump is secured in the basin to prevent m...

Страница 7: ...used Consult a licensed electrician for all wiring 3 Do not stand in water when connecting or disconnecting the power cord from the outlet 4 This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter 5 Do NOT pump flammable liquids with this pump as an explosion or fire could result 6 Do NOT run this pump dry Running this pump without water w...

Страница 8: ... responsible for losses injury or death resulting from a failure to observe these safety precautions or misuse or abuse the pumps or equipment CAUTION Do NOT wear loose clothing that may become entangled in the impeller or other moving parts Pumps generate heat and pressure during operation Allow time for pumps to cool before handling or servicing Never operate a pump with a power cord that has fr...

Страница 9: ...27 mm 5 tether or the pump will NOT turn off To allow the unit to deliver maximum capacity the sump should be kept free of accumulated sediment A 32 mm 1 discharge pipe will give best performance for this pump The vertical distance from the pump to the highest point of discharge piping should NOT exceed 6 m 20 ft Keep trash or other objects from interfering with the float Pump and Piping The pump ...

Страница 10: ...h The pump will recycle thereafter as required Allow pump to go through several cycles to assure satisfactory operation If the pump does NOT operate properly see troubleshooting checklist Refer to figure 1 for a typical installation ELECTRICAL INFORMATION The pump operates on a 115 volt 60 cycle AC single phase and has a three prong plug The third prong is used to ground the pump to prevent possib...

Страница 11: ...power cord voids the warranty Do NOT use this pump to pump liquids water in excess of 37 8 C 100 F Do NOT disassemble the motor housing This motor has NO repairable internal parts and disassembly may cause an oil leak or dangerous electrical wiring issues For proper maintenance The pump MUST be kept clean and free of debris The inlet screen prevents the passage of dirt and other solid material fro...

Страница 12: ...e 23 Oil Plug CLEANING THE PUMP 1 Always disconnect unit from power supply before any servicing is performed 2 Disconnect discharge piping and remove pump from sump basin 3 Submerse pump in a disinfectant solution Clorox or chlorine for at least one hour before disassembling pump 4 Unscrew the seven 7 stainless screws and gently pry volute from seal plate using a screwdriver 5 Use a flathead screw...

Страница 13: ...y sized for application b Incorrect voltage c Check valve stuck or installed backwards d Discharge restricted e Shut off valve closed f Impeller jammed or inlet screen plugged with debris g Pump may be air locked Start and stop pump several times h Return for service 3 Pump will not turn off a Float switch stuck in the up position Make sure it is free in basin b Tether length too long Maximum floa...

Страница 14: ...ranties to the extent permitted by law For clarity where exclusion is not permitted by law those express or implied warranties are not excluded by this warranty This warranty is subject to the following conditions and limitations 1 A bill of sale verifying the purchase and purchase date must be provided 2 This warranty will NOT apply to any product or part thereof which is worn or broken or which ...

Страница 15: ...ve material 5 Scale or corrosion buildup due to excessive chemical content 6 Any modification of the original equipment We will NOT be responsible for loss damage or labor cost due to the interruption of service caused by defective parts Neither will we accept charges incurred by others without our prior written approval This warranty is void if our inspection reveals the product was used in a man...

Страница 16: ...Toll Free 1 877 288 9888 www canaturewg com 51448 2022 01 12 ...