Страница 1: ...1 Titan Enterprises Ltd 2021 Atrato_Instruction_Manual_0322...

Страница 2: ...oftware Information 15 4 2 Window Tab Descriptions 15 4 3 User Settings Tab 17 4 3 1 Calibration Settings 17 4 3 2 Display Appearance 18 4 3 3 LCD Options 18 4 3 4 External Connections 19 Pin Assignme...

Страница 3: ...mended for highly pulsating flow systems It is not recommended for systems with entrained gas The flow tube should be kept full of liquid when powered Ultrasonic flowmeters Must be installed with posi...

Страница 4: ...to the equipment or personal injury Manufacture Information The Pulsite Link pulse convertor is designed and manufactured by Titan Enterprises Ltd Unit 2 5A Coldharbour Business Park Sherborne Dorset...

Страница 5: ...ange Please check the model number before proceeding All meters can be programmed and monitored via the USB connection ORDERING CODE First Three Digits Flow Range 710 2 500 ml min 720 0 01 1 7 l min 7...

Страница 6: ...and right hand button with local functionality Display Mode Left Hand Button Right Hand Button TOTAL Mode RESET TOTAL Press and Hold for 5 Seconds RATE Mode BOTH Mode Switches Between RATE and TOTAL o...

Страница 7: ...all the device well away from valves regulators bends and other components that could cause excessive turbulence on the fluid entering or leaving the meter If necessary use spacer blocks and mounting...

Страница 8: ...8 Titan Enterprises Ltd 2021 Atrato_Instruction_Manual_0322 Using suitable fixings mount the connection box onto a rigid surface with the cable entry preferably at the bottom...

Страница 9: ...ter will not seal if water is persistently present in this area Ensure the meter is not pressure washed The Atrato can easily be dismounted by inserting a screwdriver under the mounting clip and gentl...

Страница 10: ...76255 5V 5W supply the meter display will function as will the relay and pulse outputs require target power For full functionality including the analog outputs 15 24VDC external power is required The...

Страница 11: ...ormally closed contact 24V 100mA 4 4 20mA Analog current 4 20mA output reference to 0V 5 0 5 10V Analog voltage 0 5 10V output reference to 0V 6 PNP Output 1 open collector PNP OR Input 1 5 24V dc e g...

Страница 12: ...Software screen NOTE When correctly connected the bars will rotate in the bottom left had corner and you should see All Controls enabled along with the Meter Serial Number displayed On connecting an...

Страница 13: ...ltiple Meters If more than one meter is connected to the same PC when starting the Interface Software will open the window to choose which you wish to connect By opening another copy of the Titan Inte...

Страница 14: ...pressing the looking glass icon 4 1 3 Test Outputs This tab enables the user to manually set outputs on the Pins for testing to the target device Once the required output is selected click the Start...

Страница 15: ...ted 4 2 Window Tab Descriptions On connection with the Titan Interface Software a window will open with four tabs of settings User Settings Here you can configure how you wish the meter to present the...

Страница 16: ...ble to detach the Flow Details and Advanced windows by dragging and dropping the bottom tabs away from the main window This allows the user to view those tabs whilst adjusting the User Settings The Fl...

Страница 17: ...tions are made to scale factor Rate units per This is the time base for the flow rate and has the option of Second Minute or Hour Scale Factor Adjustment This allows the user to adjust or tune the cal...

Страница 18: ...s Display Mode Allows user to select from Rate The display will show flow rate only Total The display will show total flow only Both The display can be cycled from rate to total using the Left Hand bu...

Страница 19: ...ts the display flow switches and analog outputs from jittering with irregularities in the flow by averaging the results over a short amount of time The increments are arbitrary with the degree of damp...

Страница 20: ...7 with the exception of the transistor wiring and operation For example For PIN 7 NPN the idle state is switch open which will be a high Volt output if there is a pull up in the circuit PIN 6 PNP woul...

Страница 21: ...ic of operation can be adjusted with the Invert check box Latching This gives the user three options of None High Threshold and Low Threshold NONE will cause the alarm to be triggered when the thresho...

Страница 22: ...he alarm points This gives the user two adjustable parameters to ensure fluttering does not happen with small flow fluctuations meter response time and hysteresis Hysteresis This is used when Latching...

Страница 23: ...d Alarm can be reset by a signal Input on one of the other Input Output PINS or by Pressing and Holding the Left Hand Button on the Local Display on the Flow meter for 4 seconds The INVERT checkbox wi...

Страница 24: ...hold Unticked ON OFF Single Low Threshold Ticked OFF ON In Range Outside Range Dual None Unticked ON OFF Dual None Ticked OFF ON Dual Out of Range Unticked OFF ON Dual Out of Range Ticked ON OFF Forwa...

Страница 25: ...utput is disabled and the input pin responds to an external input voltage at TTL levels VinH 2 4V VinL 0 8V This input must be driven by an external voltage supply which can safely be in the full rang...

Страница 26: ...pins configured as alarms Reset Flowmeter Initiates the equivalent of a power on reset of the meter Start Pause Batch Starts or pauses batch Equivalent to the display left button press in batch mode...

Страница 27: ...elay is triggered Hysteresis If Positive Relay Activates above the Threshold plus the Hysteresis and deactivates when the Flow drops below the Threshold Value If Negative Relay Activates below the Thr...

Страница 28: ...atch has been delivered the meter waits for a Reset action Either the Right Hand button being pressed or from an appropriately configured input PIN 6 or 7 before preparing itself for the next batch to...

Страница 29: ...ects the meter readings showing on the Atrato LCD Display if fitted and will mimic that display The buttons either side have the functions selected on the Configuration screen and work in parallel wit...

Страница 30: ...everse flow o OR If Input is selected the Value column will show high or low depending on the switch condition and Input Logic level in the Notes column Relay If no function is set for the relay the V...

Страница 31: ...lone 237 Active Output Pulse Frequency Hz Off Low Output Alarm State No Alarm 0VDC On High Output Alarm State Alarm Triggered VDC On High Output Alarm State Invert Selected No Alarm 0V Off Low Output...

Страница 32: ...Tab 4 5 1 Interface Management To use these features it is first necessary to create a METER PIN This is a four digit number in the range 0001 to 9999 After allocating a PIN these check boxes can lock...

Страница 33: ...pletely ignored thus causing problematic readings The filter is a moving window taking the middle number from an odd number of results selectable between 1 and 21 It is not a mean and it is designed t...

Страница 34: ...far from the actual area it should be This will cause erroneous flow readings for some or all of the measurement period A power cycle will set the meter back to its calibration focus point 4 5 4 Speed...

Страница 35: ...ndow of the meter in the advanced tab feature for Fluid Speed of Sound Adjustment A bar is seen in the graph indicating whether a strong signal is being measured If a liquid has a faster speed of soun...

Страница 36: ...nternal to the flowmeter but stored to the connected PC and therefore only occurs whilst the PC is connected to the meter Simply check the relevant parameter you wish to log choose a sensible sampling...

Страница 37: ...Once all is selected correctly the Start Logging button will become enabled Click it to start the data logging file creation In the bottom left corner the samples collected will be listed as the log...

Страница 38: ...1000Hz Relay 24V dc 500mA max non inductive PIN 6 transistor output PNP 24V 20mA maximum Input Pull down resistor required 10k PIN 7 transistor output NPN 24V 20mA maximum Input Pull up resistor requ...

Страница 39: ...ittings PEEK food and medical grade or 316 Stainless steel Flow tube 316 Stainless Steel as standard Alternative Boroscilicate glass Seals Viton as standard Alternative Nitrile EPDM Silicone Kalrez Ho...

Страница 40: ...al strength Back Pressure too low for adequate signal Increase Back Pressure to 500mbar 2 x vapour pressure of the liquid Gas in flow meter Increase flow to purge line Ensure position optimum for ensu...

Страница 41: ...wired correctly according to the diagrams in the manual No Pulse Output on output or showing on Titan Interface Software Reverse Flow Check Settings installation If reverse flow is required to give a...

Страница 42: ...ir Titan Interface Software is not showing all Tabs User Settings Flow Details Advanced Datalogging Software is placing the tab window outside the monitor area Go to View on the top bar menu and click...