Rack Control Module
TM
Product Manual
Rev. 1.2, May 9, 2014
Page 37
T
P
M
0
0
7
For Single or Dual TD80 Systems:
Permit: RED
Sensor 1: OFF
Sensor 2: RED
Power: SOLID YELLOW
WHAT TO DO:
DETAILS:
WHAT TO CHECK:
REMEDY:
Check the Finch
display for an
active alarm,
system error
code or loss of
communication
Clear the alarm
or resolve the
TD80 system
malfunction
If the alarm
clears, no system
errors or loss of
communication
and Sensor 2
remains RED
1. Check for loose
or broken wiring
at the RCM
junction box.
Repair or replace
the wiring.
2. Check the wiring
between the
junction box and
RCM. Repair the
wiring or replace
the RCM.
For Single or Dual TD80 Systems:
Permit: RED
Sensor 1: RED
Sensor 2: RED
Power: SOLID YELLOW
WHAT TO DO:
DETAILS:
WHAT TO CHECK:
REMEDY:
Check the Finch
display for an
active alarm,
system error
code or loss of
communication
Clear the alarm
or resolve the
TD80 system
malfunction
If the alarm
clears, no system
errors or loss of
communication
and Sensor 1 and
2 remains RED
1. Check for loose
or broken wiring
at the RCM
junction box.
Repair or replace
the wiring.
2. Check the wiring
between the
junction box and
RCM. Repair the
wiring or replace
the RCM.