controller leaves the ‘CO2 OUTLET’ active until the temperature set point is exceeded. When
this occurs, the ‘CO2 OUTLET’ is deactivated and then the ‘FAN OUTLET’ is activated; and
your exhaust fan will run until the temperature is lower than your preferred setting. After
the temperature has lowered below the selected temperature level the ‘FAN OUTLET’ is
defeated and the ‘CO2 OUTLET’ is activated and can begin dosing your garden with CO2
again, if required. This innovative function serves two purposes: One, this allows maximum
CO2 coverage with minimum CO2 waste; Two, your exhaust fan is working only when it is
required - saving power and wear & tear on your gear. At any time if the humidity set point is
exceeded, the controller will activate the ‘HUMIDITY OUTLET’ and reduce the humidity level
to below your preferred humidity setting. During the nighttime hours the controller defeats
the ‘CO2 OUTLET’ (No need for CO2 at night) and activates the ‘NIGHT OUTLET’. The
‘NIGHT OUTLET’ may be used to operate a circulation fan, CO2 exhaust fan using a short
cycle timer, garden maintenance night light or any other device that you would like only to
run during the nighttime hours. If during the nighttime hours the temperature exceeds your
preferred setting, then the ‘FAN OUTLET’ is activated to lower the temperature to desired
levels. If the humidity set point is exceeded during the nighttime hours, then the ‘HUMIDITY
OUTLET” is activated and will lower the gardens humidity to desired levels. This provides
the grower with 24 hour temperature and humidity control. The Saturn
™
2 is built with the
highest quality components to provide the user with years of trouble free service. Controllers
created for our industry, by our industry!
Instructions for Operation
• Securely mount your Saturn
™
2 in your grow area and away from any moisture, spray,
pesticides, etc. using the mounting brackets and hardware provided.
• Plug the exhaust fan into the ‘FAN OUTLET’.
• Turn the fan ‘ON’ to the highest setting possible, if adjustable.
• Plug the CO2 Controller (Atlas
®
Series CO2 Controller) or a repeat cycle timer (Apollo
™
series timers) into the “CO2 OUTLET’. Then, plug your CO2 Generator or CO2 Regulator/
Tank into the CO2 controller or repeat cycle timer (See Installation Example section for
more information)
• The integrated photocell ensures that the CO2 generator or CO2 tank only activate when
your garden is in the daytime hours (lights are ‘ON’). This is when your plants uptake CO2
and can gain the most benefits from enriching the environment with CO2. To preserve
your CO2, the ‘CO2 OUTLET’ is automatically disabled when your ‘FAN OUTLET’ is active
or in your garden’s nighttime hours.
• When the ‘CO2 OUTLET’ is disabled during daytime hours because of excessive
temperature, the ventilation process begins and continues until the temperature level has
lowered to below your preferred setting on the temperature dial. After the temperature
drops to below the preferred temperature setting, then the ‘CO2 OUTLET’ is reactivated
and resumes normal functioning.
• Plug your circulation fan, short cycle timer for CO2 exhaust fan, or garden maintenance
night light into the “NIGHT OUTLET’.
• Plug the dehumidifier into the ‘HUMIDITY OUTLET’
• Turn the dehumidifier ‘ON’ to the lowest setting. This allows the controller to maintain
precise control of the humidity in your garden.
• Set the ‘Temperature’ and ‘Humidity’ dials at the preferred temperature and humidity
levels for your garden.
Warranty Information
• Titan Controls
®
warrants the original purchase of this product against defects in material
and workmanship under normal use for three (3) years from the date of purchase.
• During the warranty period, Titan Controls
®
will, at our option, and without charge, repair or
replace this product if the controller or any of its components fail or malfunction.
• All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA)
number prior to any service of the product.
• This warranty is in lieu of all other warranties, expressed or implied, including the warranties
of merchantability and fitness for use, and of all other obligations or liabilities on the part of
the seller.
• This warranty shall not apply to this product or any part thereof which had been damaged
by accident, abuse, misuse, modification, negligence, alteration or misapplication.
• Controllers with serial numbers or date tags that have been removed, altered or obliterated;
broken seals that show evidence of tampering; mismatched board serial numbers or
nonconforming parts, are excluded from coverage.
• Titan Controls
®
makes no warranty whatsoever in respect to accessories or parts not
supplied by Titan Controls
®
.
• Monetary refunds of the warranty will not be given.
• The Buyer assumes all responsibility regarding the proper use & installation of this
controller.
• All warranty service is provided through the Titan Controls
®
factory.
• This warranty shall apply only to the United States, including Alaska, Hawaii and territories
of the United States.
• Defective controllers are required to be returned with the “proof of purchase/receipt” for
warranty coverage.
• For additional warranty information, contact the Titan Controls
®
Technical Service
Representative or your local Dealer.
• NOTE: Titan Controls
®
is a Manufacturer of environmental, timing, lighting, ventilation and
CO2 controls. All sales offerings to the public are done through a nationwide group of
Dealers. No sales offerings will be made directly to the general public.
Service and Repair Program
• For all service and repairs, please contact by our Technical Service Representative for
troubleshooting your gear and attaining a Return Merchandise Authorization (RMA) number,
if applicable.
• All factory service & repairs will be completed within 48 hours of receipt of controller at the
factory.
• Titan Controls
®
will, at its discretion, repair or replace the controller.
• Factory calibration services are available for all Titan Controls
®
.
• Returning Units: Please contact your retail store for information regarding returns.